Related Experiment Video
Updated: Jan 24, 2026

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Published on: June 7, 2015
Potential applications of the quantitative susceptibility mapping (QSM) in MR-guided radiation therapy
Reyhaneh Nosrati1,2,3,4, Moti Paudel5,6, Ananth Ravi5,6
1Department of Physics, Ryerson University, Toronto, Canada.
Abstract:
Magnetic resonance-guided radiation therapy (MR-GRT) offers great potential to improve radiation treatment outcomes by providing more accurate and patient-tailored therapy. Despite superior soft tissue contrast in MRI, one of the challenges towards MRI-only workflows is that the process often requires some sort of 'MR-invisible' metal-based devices. In this study, the feasibility of quantitative susceptibility mapping (QSM) for visualization of some MR-invisible radiation therapy devices was studied. Our recently proposed QSM-based algorithm for brachytherapy seed visualization was modified and the feasibility of the optimized algorithm for visualization of different devices including: brachytherapy seeds, plastic interstitial needles, CT-markers and obturators, and different types of fiducial markers in agar, prostate and meat phantoms were studied. All phantoms were scanned using 3T MR scanner with a 3D multi-echo gradient recalled echo (ME-GRE) pulse sequence. The QSM results in all phantoms were compared to CT images for spatial accuracy of the QSM. The applied post-processing algorithm was found to be insensitive to the seeds' type; also, presence of nearby calcifications had no effect on seed visualization. QSM successfully generated positive contrast for both types of investigated fiducial markers with high spatial accuracy compared to CT. Interstitial needles containing both aluminum-based CT-maker and titanium-based obturators were accurately depicted on the QSM. The proposed QSM-based technique relies on the standard MR pulse sequences and visualize the conventional MR-invisible metallic devices with CT-like positive contrast solely through post-processing. Upon in vivo validation of the technique, QSM may have the potential to replace CT for an MR-only guided radiation therapy.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Related Concept Videos
Radiation: Applications
The average...
Biological Effects of Radiation
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Absorption of Radiation
Generating Electromagnetic Radiations
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force...