Related Experiment Video
Updated: Jan 24, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
The impact of dose algorithms on tumor control probability in intensity-modulated proton therapy for breast cancer
Xiaoying Liang1, Julie A Bradley1, Dandan Zheng2
1Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, FL, USA.
Purpose:
To evaluate the radiobiological impact of PB algorithm versus MC algorithm in intensity-modulated proton therapy (IMPT) plans for breast cancer treatment.
Methods:
20 breast cancer patients who received IMPT to the breast/chest wall and regional lymphatics were included in this study. For each patient, 2 IMPT plans were generated: a PB-optimized plan and a MC-optimized plan. The radiobiological and dosimetric impact to the CTV of the dose algorithms was assessed. The Poisson Linear-Quadratic model was used to estimate the tumor control probability (TCP). The influence of the model parameter uncertainties on the TCP was tested against different sets of published model parameters.
Results:
The PB-optimized plans significantly under-dosed the target as compared to the MC-optimized plans. The median (range) differences in CTV D95% and CTV Dmean were 1.9 (1.2-3.1) Gy and 1.2 (0.5-1.9) Gy, corresponding to 3.8% (2.4-6.2%) and 2.4% (1.0-3.8%) of the prescription dose. The TCP was lower in the PB-optimized plans than the MC-optimized plans. The median (range) of the TCP differences (ΔTCP) were 4% (2-6%), 3% (2-5%), and 2% (1-3%), respectively, when calculated using 3 different model parameter sets. The ΔTCP correlated with the CTV dose difference, and moderately correlated with the CTV volume.
Conclusion:
Due to the inaccurate dose modeling, PB-optimized plans under-dose the target and therefore yield a lower TCP compared to MC-optimized plans in breast IMPT. The magnitude of the resulting difference in TCP reached 6% in our study.
Related Concept Videos
Probability Laws
Cancer Therapies
However, cancer treatments can pose several challenges, as therapies used to kill cancer cells are generally also toxic to normal cells. Moreover, cancer cells mutate rapidly and can develop resistance to chemical agents or radiation therapy. Besides, all types of cancer cells may not respond to the same therapy. Some cancer cells respond to one...
Targeted Cancer Therapies
There are several types of targeted therapies against...
Probability in Statistics
An example of a simple event is a coin toss. The result of a coin toss is either a head or a tail. Here, head and tail are two simple events. These two simple events make up the sample space. Further, the probability of an event occurring falls within the range of 0 to 1. The probability of an...
Probability Histograms
Probability Distributions
A discrete probability distribution is a probability distribution of discrete random variables. It can be categorized into binomial probability distribution and Poisson...