Trajectory control of electron beams using high intensity permanent magnests for linac-adaptable convergent beam
R G Figueroa1, L Rojas2, M Valente3
1Centro de Física e Ingeniería en Medicina, CFIM, Universidad de La Frontera, Temuco, Chile; Departamento de Ciencias Físicas, Universidad de La Frontera, Temuco, Chile.
Abstract:
Convergent beam radiotherapy, or CBRT, currently under development is based on the adaptation of a linear accelerator (linac) to a device which allows to dynamically curve the original trajectory of the electron beam so that it impacts upon a target. This produces a photon beam via Bremsstrahlung which converges on a predetermined focus point (isocenter). Adaptation of the RTHC device is only possible if it is sufficiently compact, as the device must be placed between the linac head exit and the gurney. This requires that new magnetic deflection devices be developed. This paper describes the theoretical and experimental development of controlled-deflection electron beam systems (at energies in MeV ranges) generated in a dual linear accelerator waveguide. A device which follows RTHC geometry is adapted for the system, using new magnetic deflector designs based on permanent neodymium magnets which reach magnetic field intensities in the order of Tesla. The methodology that was developed includes calculations of the radii of curvature with relativistic considerations for mono- and poly-energetic electrons. Deflection angles were calculated based on this theoretical foundation, using a program developed in MatLab® which shows the trajectory of electrons both under ideal conditions (uniform magnetic field) and real conditions (magnetic field defined through intensity distribution). Monte Carlo simulation subroutines were implemented in order to estimate the spectrum of electrons issuing from the linac as well as to directly determine the electron beam trajectory with magnetic deflectors present. Theoretical and simulated results were compared to experiments performed with a clinical linear accelerator, demonstrating correspondence between different methodologies and confirming the ability to achieve electron beam deflection levels necessary for implementation of convergent beam radiotherapy device.
Related Concept Videos
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Prismatic Beams: Problem Solving
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...
Principal Stresses in a Beam
Analyzing principal stresses is crucial, especially in...
Beams with Symmetric Loadings
The M/EI...
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...