Related Experiment Video
Updated: Jan 24, 2026

Implantation of Human-Sized Coronary Stents into Rat Abdominal Aorta Using a Trans-Femoral Access
Published on: November 19, 2020
Characterisation and constitutive modelling of biaxially stretched poly(L-lactic acid) sheet for application in
R W Blair1, N J Dunne2, A B Lennon1
1School of Mechanical and Aerospace Engineering, Queen's University, BT9 5AH, Belfast, UK.
Abstract:
A poly(L-lactic acid) stent is exposed to a variety of processing techniques, temperatures and environmental conditions during its lifecycle, from the manufacturing process, to crimping through to deployment within the body. The effect of the biaxial stretching procedure and the effects of temperature and extension rate (post-processing) on the mechanical response of poly(L-lactic acid) are hereby investigated, and a constitutive model calibrated against experimental data is proposed. Dumb-bell specimens were punched from biaxially stretched sheets subjected to different processing histories, and tested under uniaxial tension at various temperatures (20, 37 and 55 °C) and extension rates (1, 5 and 10 mm/min). A Design of Experiments methodology was employed to identify the parameters that had the most significant effect on the mechanical response of the polymer. Results show that the elastic modulus and yield strength of the stretched sheets are strongly dependent on the aspect ratio of the biaxial deformation, along with the temperature during uniaxial deformation (post-processing). In contrast, these mechanical properties were not heavily dependent on extension rate (post-processing). A transversely isotropic, elastic-plastic constitutive model for finite element implementation is proposed, with the intention that it may be used as a design tool for developing high stiffness, thin-strut polymeric stents that contend with the performance of their metallic counterparts.
More Related Videos
Related Concept Videos
Constitutional Isomers of Alkanes
The linear isomer of an alkane is prefixed by the term “n”; hence a linear isomer of pentane is known as n-pentane. Based on the type of branching, some of the...
Constitutive and Regulated Gene Expression
Flow Sheet
Here's a closer look at the examples of flowsheets commonly used by nurses:
Graphic Sheet Documentation:
IR Frequency Region: X–H Stretching
IR Frequency Region: Alkyne and Nitrile Stretching
Comparing the stretching vibrational frequency of C≡C triple bonds with that of double and single bonds, it is evident that C≡C triple bonds exhibit a higher stretching frequency than C=C double and C–C single bonds. Similarly, the C≡N triple bond...
IR Frequency Region: Alkene and Carbonyl Stretching
Stretching frequencies are affected by several factors, such as resonance, inductive effects, ring strain, dipole moment, and hydrogen bonding. Consequently, the stretching frequency of the carbonyl double bond...