Background:
Dynamic contrast enhanced (DCE) MRI parameters are potential biomarkers to characterise tumour vasculature and distinguish it from the non-cancerous blood vessel system within the prostate. However, the inevitable presence of intra- and inter-observer variabilities is challenging in this context. Additionally, pre-contrast T1-time correction is a prerequisite to gain quantitative DCE parameters in the first place. The current study investigated the effect of individualized T1-time correction on intra- and inter-reader variability for quantitative DCE-parameters in prostatic lesions.
Methods:
In this IRB-approved retrospective study, two experienced radiologists assessed DCE parameters using individually measured (A) and fixed (B) T1-times twice with a time difference of three weeks. The dataset consisted of 35 MRI-guided biopsy-proven prostate cancer lesions. Limits of agreement (LoA) and coefficients of variability (CoV) were calculated to assess intra- and inter-reader variabilities of the parameters.
Results:
With exception of kep, for all DCE parameters both intra- and inter-reader CoV were smaller in B compared to A. Absolute kep values were largely insensitive to T1-time correction induced bias. The mean intra-reader CoVs [5%, 95% percentile] (over all four DCE parameters and both readers) were 6.7% [0.5%, 15.1%] in A and 3.9% [0.2%, 11.0%] in B. The inter-reader CoVs were 9.0% [0.6%, 25.8%] (A) and 7.0% [0.3%, 25.4%] (B).
Conclusions:
T1-time correction has a significant influence on the intra- and inter-reader variability. By applying individually measured T1-time correction, both intra- and inter-observer variability were found to increase. Out of all investigated DCE parameters, kep is the most robust to this investigated bias.
More Related Videos
06:24Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model
Published on: April 18, 2015
07:25A Bioluminescent and Fluorescent Orthotopic Syngeneic Murine Model of Androgen-dependent and Castration-resistant Prostate Cancer
Published on: March 6, 2018
Related Concept Videos
The Integrated Rate Law: The Dependence of Concentration on Time
Chronopharmacokinetics: Time-Dependent Pharmacokinetics
Time-dependent pharmacokinetics refers to non-cyclical changes in drug rate processes over a period of time. It can lead to nonlinear pharmacokinetics, where the relationship between drug concentration and time is not proportional. Non-cyclical...
Naturalistic Observations
Distance Corrections
Common Ion Effect
Frequency-dependent Selection