Related Experiment Video
Updated: Jan 24, 2026

Porcine Model of Infrarenal Abdominal Aortic Aneurysm
Published on: November 21, 2019
Computational analysis of renal artery flow characteristics by modeling aortoplasty and aortic bypass interventions
Christopher Tossas-Betancourt1, Theodorus M J van Bakel2, Christopher J Arthurs3
1Department of Biomedical Engineering, University of Michigan, Ann Arbor, Mich.
Objective:
Suprarenal abdominal aortic coarctation (SAAC) alters flow and pressure patterns to the kidneys and is often associated with severe angiotensin-mediated hypertension refractory to drug therapy. SAAC is most often treated by a thoracoabdominal bypass (TAB) or patch aortoplasty (PA). It is currently unclear what effect these interventions have on renal flow and pressure waveforms. This study, using retrospective data from a patient with SAAC subjected to a TAB, undertook computational modeling to analyze aortorenal blood flow preoperatively as well as postoperatively after a variety of TAB and PA interventions.
Methods:
Patient-specific anatomic models were constructed from preoperative computed tomography angiograms of a 9-year-old child with an isolated SAAC. Fluid-structure interaction (FSI) simulations of hemodynamics were performed to analyze preoperative renal flow and pressure waveforms. A parametric study was then performed to examine the hemodynamic impact of different bypass diameters and patch oversizing.
Results:
Preoperative FSI results documented diastole-dominated renal perfusion with considerable high-frequency disturbances in blood flow and pressure. The postoperative TAB right and left kidney volumes increased by 58% and 79%, respectively, reflecting the increased renal artery blood flows calculated by the FSI analysis. Postoperative increases in systolic flow accompanied decreases in high-frequency disturbances, aortic pressure, and collateral flow after all surgical interventions. In general, lesser degrees of high-frequency disturbances followed PA interventions. High-frequency disturbances were eliminated with the 0% PA in contrast to the 30% and 50% PA oversizing and TAB interventions, in which these flow disturbances remained.
Conclusions:
Both TAB and PA dramatically improved renal artery flow and pressure waveforms, although disturbed renal waveforms remained in many of the surgical scenarios. Importantly, only the 0% PA oversizing scenario eliminated all high-frequency disturbances, resulting in nearly normal aortorenal blood flow. The study also establishes the relevance of patient-specific computational modeling in planning interventions for the midaortic syndrome.
Related Concept Videos
Aortic Regurgitation I: Introduction
General Characteristics of Pipe Flow I
The classification of fluid...
General External Flow Characteristics
General Characteristics of Pipe Flow II
The distance to reach a fully developed flow is called the entrance length and depends on the...
Aortic Regurgitation III: Medical Management
Aortic Regurgitation IV: Nursing Management