Shear Wave Elastography (SWE) for the Evaluation of Patients with Plantar Fasciitis
Matthias Gatz1, Ljudmila Bejder1, Valentin Quack1
1Department of Orthopedics, University Hospital RWTH Aachen, Pauwelsstraße 30, Aachen 52074, Germany.
Rationale And Objectives:
The current imaging standard for diagnosing plantar fasciitis is B-Mode ultrasound (B-US). The aim of this study was to determine the diagnostic potential of Shear Wave Elastography (SWE) and the correlation of clinical scores to elastographic parameters.
Materials And Methods:
Diagnostic case-control study with n = 82 plantar fascia (PF). PF were divided into three subgroups: (1) symptomatic PF (n = 39); (2) control group of unilateral asymptomatic PF (n = 23); (3) bilateral asymptomatic PF (n = 20). Reference standard for positive findings in B-US was a PF thickness greater than 4 mm. For SWE tissue elasticity (Young's modulus kPa; shear wave speed m/s) was measured at Location 1: directly at the calcaneus; Location 2: +1 cm distal of the calcaneus and Location 3: central part of the calcaneus. Sensitivity, specificity, and diagnostic accuracy as well as correlation to American Orthopaedic Foot and Ankle Score (AOFAS) and Food Functional Index (FFI) were determined.
Results:
Symptomatic PF are thicker (4.2 mm, n = 39) than asymptomatic (3.0 mm, n = 43) (p < 0.001). Thickness of the PF (n = 82) correlated poorly to clinical scores (p = 0.001): FFI-pain (r = 0.349); FFI-function (r = 0.381); AOFAS (r = -0.387). Cut-off point for positive SWE finding was 51.5 kPa (4.14 m/s). Symptomatic PF (31.9 kPa, 3.26 m/s, n = 39) differ significantly from asymptomatic PF (93.3 kPa, 5.58 m/s, n = 43) with significant differences at L1 between all groups (p < 0.001). Correlation between Young's modulus (n = 82) and clinical scores was strong (p < 0.001): FFI-pain (r = -0.595); FFI-function (r = -0.567); AOFAS (r = 0.623,). B-US: sensitivity (61%), specificity (95%); SWE sensitivity (85%), specificity (83%). The combination of SWE and B-US increases the sensitivity (100%) with a diagnostic accuracy of 90%.
Conclusion:
Based on our results, we could show that SWE can improve the diagnostic accuracy in patients with plantar fasciitis compared to B-US.
Level Of Evidence:
II.
More Related Videos
05:56Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
Published on: August 29, 2025
02:15Predictive Measurement for Windlass Change in Length and Selected Treatment Outcomes in Chronic Plantar Fasciitis
Published on: March 1, 2024
Related Concept Videos
The Wave Nature of Light
Shearing Stress
The average shearing stress can be calculated by dividing the shear by the area of the cross-section.
Shearing Strain
Shear Diagram
First, a free-body diagram of the beam is drawn, representing all the external forces and internal reactions acting on the beam. One can calculate the reaction forces at each support by employing the equilibrium equations of force and moment. The vertical component...
Half wave rectifier
Full wave rectifier