Related Experiment Video
Updated: Jan 24, 2026

Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Determination of epoxide impurity in sarpogrelate hydrochloride intermediate by UHPLC and column-switching liquid
Ran Wang1, Zhiling Zhu1, Xiaodan Qiu1
1Institute of Medicinal Biotechnology, Peking Union Medical College & Chinese Academy of Medical Sciences, No 1, Tiantan Xili, Beijing 100050, PR China.
Abstract:
The determination of genotoxic impurities, which is closely related to toxicological concern and daily dose, plays a key role in drug quality control. Epoxide impurity is a kind of genotoxic impurity with an epoxy ring structure during the synthesis process of sarpogrelate hydrochloride. According to the sarpogrelate hydrochloride daily dose, epoxide impurity is limited to the under 5 ppm level. The liquid chromatographic-tandem mass spectrometric (LC/MS/MS) or the gas chromatography-mass spectrometric (GC/MS) method is commonly used to characterize the epoxide impurity of sarpogrelate hydrochloride intermediates. However, these methods are not simple or economical enough to detect epoxide impurity. In this study, we resolved the problem by using the most common UV method with two ideas: one was to improve the absolute sensitivity, and the other was to reduce matrix effects. Both ultra high-performance liquid chromatography (UHPLC with high sensitivity LightPipe™ flow cells) and column-switching liquid chromatography methods were developed and validated for the quantitative determination of epoxide impurity in sarpogrelate hydrochloride intermediates. The limits of detection (LODs) of the UHPLC and column-switching liquid chromatography methods were 0.09 ppm (0.09 μg/g) and 0.33 ppm (0.33 μg/g), and the recovery rates of both methods were 87.2%-132.1% and 97.4%-100.1%, respectively. Both methods established and provided guidance for analysts to develop procedures for impurity control, especially for structures of impurity with similar matrices.
More Related Videos
08:54Determining Four Components in a Lipid Nanoparticle RNA Delivery System by Liquid Chromatography Combined with Evaporative Light Scattering Detector
Published on: May 30, 2025
10:21Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Related Concept Videos
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Principles Of Column Chromatography
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: