Related Experiment Video
Updated: Jan 24, 2026

Prostaglandin Extraction and Analysis in Caenorhabditis elegans
Published on: June 25, 2013
Stability of prostaglandin E1 solutions stored in polypropylene syringes for continuous intravenous administration to
David Palmero1,2, Emilienne Chavan1,2, Markoulina Berger-Gryllaki1
1Department of Pharmacy, Lausanne University Hospital, Lausanne, Switzerland.
Objective:
We aimed to monitor the physicochemical stability of prostaglandin E1 (PGE1) 1.5 and 15 µg/mL in 10% dextrose stored in polypropylene syringes.
Methods:
We developed a liquid chromatography-high resolution mass spectrometry (LC-HRMS) method to detect and quantify levels of PGE1. Method selectivity was performed with a mixture of PGE1 and its degradation products. Forced degradation tests were performed to determine which degradation products were most likely to form. PGE1 injection solutions in 10% dextrose were stored in unprotected and shielded-from-light polypropylene syringes in a climatic chamber. Samples were taken immediately after preparation (T0) and after 24, 48, 72 and 168 hours for analysis. PGE1 solutions were considered stable if ≥90.0% of the initial concentration was retained.
Results:
The LC-HRMS method was validated in the range of 0.086-0.200µg/mL PGE1 with trueness values between 98.2% and 100.3%, and repeatability and intermediate precision values of <2.2%and <4.7%, respectively. The quantification and detection limits of the method were 0.086 and 0.026µg/mL, respectively. PGE1 and its degradation products were resolved chromatographically. PGE1 injection solutions were≥90.0%stable after 48hours in unprotected from light (UPL) syringes. The solutions remained clear without precipitation, colour or pH modification and subvisible particles within the permitted levels. Prostaglandin A1 was the sole degradation product observed.
Conclusions:
A LC-HRMS method to evaluate PGE1 stability in a 10% dextrose was developed and validated. PGE1 1.5 and 15µg/mL in 10% dextrose solution are stable for 48hours when stored at 30ºC in UPL polypropylene syringes.
Related Concept Videos
BIBO stability of continuous and discrete -time systems
To determine the BIBO stability, the convolution integral is utilized when a bounded continuous-time input is applied to a Linear Time-Invariant (LTI) system....
Energy Stored in a Capacitor
E1 Reaction: Kinetics and Mechanism
E1 Reaction: Stereochemistry and Regiochemistry
Energy Stored in Capacitors
By integrating the equation that relates voltage and current in a capacitor, one can derive an equation for the voltage across the capacitor at any given time. This equation is crucial in understanding and predicting the behavior of capacitors in...
Energy Stored in Inductors
In terms of gauging the energy stored within an inductor, it is equivalent to the integral of the power delivered at every individual moment, all...