Related Experiment Video
Updated: Jan 24, 2026

A Novel Surgical Technique in a Sheep Model for Suburethral Graft Implantation
Published on: June 20, 2025
Comparison of Three Different Techniques on the Movement of Implants After Evisceration
Selam Yekta Sendul1, Aysegul Mavi Yildiz2, Burcu Dirim1
1Sisli Hamidiye Etfal Training and Research Hospital, Department of Ophthalmology.
Purpose:
To compare the results of 3 evisceration techniques involving placement of an acrylic implant within the scleral shell without posterior sclerotomy (Group 1), posterior sclerotomy with placement of a porous implant within the intraconal space (Group 2) and posterior sclerotomy with placement of a acrylic implant within the intraconal space (Group 3) with respect to ocular mobility, implant complications and patient satisfaction.
Methods:
Single-center, retrospective, interventional case series. A chart review of 72 patients undergoing evisceration between February 2013 and January 2018 was carried out. Thirty-five patients met the inclusion criteria having a normal or near normal size eye and at least 6 months follow-up. The horizontal movements of the implant and the artificial eye was measured by using a ruler. Data analyses were conducted using the Mann-Whitney U test for 2 independent samples.
Results:
Neither infection nor prolapse of the implant had occurred in any of the patients. The mean implant sizes were 18 mm in Group 1, 20 mm in Group 2 and 20 mm in Group 3. Statistically, a significant difference was assessed between Group 1 and Group 2 in both nasal and temporal movement of the socket; nasal and temporal movement of the prosthesis. Statistically, a significant difference was assessed between Group 1 and Group 3 in both nasal and temporal movement of the socket; nasal and temporal movement of the prosthesis. However, there was no statistically significant difference between Group 2 and Group 3 in neither nasal and temporal movement of the socket nor nasal and temporal movement of the artificial eye.
Conclusion:
Group 1 showed the significantly better movement of both prosthesis and socket in adduction and abduction than Group 2 and 3. The likely explanation for this may be that preserving the scleral shell integrity allows more efficient transmission of muscle contraction to the socket and prosthesis.
More Related Videos
10:00Techniques for Processing Eyes Implanted with a Retinal Prosthesis for Localized Histopathological Analysis: Part 2 Epiretinal Implants with Retinal Tacks
Published on: February 14, 2015
05:51Computed Tomography (CT) Guided Implantation of a Totally Implantable Venous Access Port (TIVAP) through Subclavian Vein
Published on: January 13, 2026
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Anatomical Movements
Here are some common anatomical movements:
Flexion and extension motions are in the sagittal (anterior–posterior) plane of motion. These movements take place at the shoulder, hip, elbow, knee, wrist,...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
The Movement of Organelles and Vesicles
Movement Joints in Buildings
The simplest type of movement joints, working joints, are...
Fluid Movement Between Compartments