Atomic Absorbance Spectroscopy to Measure Intracellular Zinc Pools in Mammalian Cells
Published on: May 16, 2019
Atomic Absorbance Spectroscopy to Measure Intracellular Zinc Pools in Mammalian Cells
Shellaina J V Gordon1, Yao Xiao2, Amanda L Paskavitz3
1Department of Biochemistry and Molecular Pharmacology, University of Massachusetts Medical School.
Abstract:
Transition metals are essential micronutrients for organisms but can be toxic to cells at high concentrations by competing with physiological metals in proteins and generating redox stress. Pathological conditions that lead to metal depletion or accumulation are causal agents of different human diseases. Some examples include anemia, acrodermatitis enteropathica, and Wilson's and Menkes' diseases. It is therefore important to be able to measure the levels and transport of transition metals in biological samples with high sensitivity and accuracy in order to facilitate research exploring how these elements contribute to normal physiological functions and toxicity. Zinc (Zn), for example, is a cofactor in many mammalian proteins, participates in signaling events, and is a secondary messenger in cells. In excess, Zn is toxic and can inhibit absorption of other metals, while in deficit, it can lead to a variety of potentially lethal conditions. Graphite furnace atomic absorption spectroscopy (GF-AAS) provides a highly sensitive and effective method for determining Zn and other transition metal concentrations in diverse biological samples. Electrothermal atomization via GF-AAS quantifies metals by atomizing small volumes of samples for subsequent selective absorption analysis using wavelength of excitation of the element of interest. Within the limits of linearity of the Beer-Lambert Law, the absorbance of light by the metal is directly proportional to concentration of the analyte. Compared to other methods of determining Zn content, GF-AAS detects both free and complexed Zn in proteins and possibly in small intracellular molecules with high sensitivity in small sample volumes. Moreover, GF-AAS is also more readily accessible than inductively coupled plasma mass spectrometry (ICP-MS) or synchrotron-based X-ray fluorescence. In this method, the systematic sample preparation of different cultured cell lines for analyses in a GF-AAS is described. Variations in this trace element were compared in both whole cell lysates and subcellular fractions of proliferating and differentiated cells as proof of principle.
Related Concept Videos
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Fluorescence Spectroscopy
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Emission Spectroscopy: Lab
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...