Related Experiment Video
Updated: Jan 24, 2026

Use of MRI-ultrasound Fusion to Achieve Targeted Prostate Biopsy
Published on: April 9, 2019
Optimizing the Number of Cores Targeted During Prostate Magnetic Resonance Imaging Fusion Target Biopsy
Alexander P Kenigsberg1, Audrey Renson2, Andrew B Rosenkrantz3
1Division of Urologic Oncology, Department of Urology, New York University Langone Health, New York, NY, USA.
Background:
The number of prostate biopsy cores that need to be taken from each magnetic resonance imaging (MRI) region of interest (ROI) to optimize sampling while minimizing overdetection has not yet been clearly elucidated.
Objective:
To characterize the incremental value of additional MRI-ultrasound (US) fusion targeted biopsy cores in defining the optimal number when planning biopsy and to predict men who might benefit from more than two targeted cores.
Design, Setting, And Participants:
This was a retrospective cohort study of MRI-US fusion targeted biopsies between 2015 and 2017.
Intervention:
MRI-US fusion targeted biopsy in which four biopsy cores were directed to each MRI-targeted ROI.
Outcomes Measurements And Statistical Analysis:
The MRI-targeted cores representing the first highest Gleason core (FHGC) and first clinically significant cancer core (FCSC; GS≥3+4) were evaluated. We analyzed the frequency of FHGC and FCSC among cores 1-4 and created a logistic regression model to predict FHGC >2. The number of unnecessary cores avoided and the number of malignancies missed for each Gleason grade were calculated via clinical utility analysis. The level of agreement between biopsy and prostatectomy Gleason scores was evaluated using Cohen's κ.
Results And Limitations:
A total of 479 patients underwent fusion targeted biopsy with four individual cores, with 615 ROIs biopsied. Among those, FHGC was core 1 in 477 (76.8%), core 2 in 69 (11.6%), core 3 in 48 (7.6%), and core 4 in 24 men (4.0%) with any cancer. Among men with clinically significant cancer, FCSC was core 1 in 191 (77.8%), core 2 in 26 (11.1%), core 3 in 17 (6.2%), and core 4 in 11 samples (4.9%). In comparison to men with a Prostate Imaging-Reporting and Data System (PI-RADS) score of 5, patients were significantly less likely to have FHGS >2 if they had PI-RADS 4 (odds ratio [OR] 0.287; p=0.006), PI-RADS 3 (OR 0.284; p=0.006), or PI-RADS 2 (OR 0.343; p=0.015). Study limitations include a single-institution experience and the retrospective nature.
Conclusions:
Cores 1-2 represented FHGC 88.4% and FCSC 88.9% of the time. A PI-RADS score of 5 independently predicted FHGC >2. Although the majority of cancers in our study were appropriately characterized in the first two biopsy cores, there remains a proportion of men who would benefit from additional cores.
Patient Summary:
In men who undergo magnetic resonance imaging-ultrasound fusion targeted biopsy, the first two biopsy cores diagnose the majority of clinically significant cancers. However, there remains a proportion of men who would benefit from additional cores.
More Related Videos
06:08A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
Published on: March 21, 2025
05:49Use of Magnetic Resonance Imaging and Biopsy Data to Guide Sampling Procedures for Prostate Cancer Biobanking
Published on: October 10, 2019
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Nuclear Fusion
A helium nucleus has a mass that is 0.7% less than that of four hydrogen nuclei; this lost mass is converted into energy during the fusion. This reaction produces about...
Targeted Cancer Therapies
There are several types of targeted therapies against...
Atomic Nuclei: Magnetic Resonance
Targets for Drug Action: Overview
Receptors are either membrane-spanning or intracellular proteins, which upon binding a ligand, get activated and transmit the signal downstream to elicit a response. Drugs bind receptors, either mimicking the action of endogenous ligands or blocking the receptor activity to bring about a modified response. Nearly 35% of approved drugs target the G...