Small-Size vs Large-Size Burr for Rotational Atherectomy
Yaniv Levi, Shahar Lavi, Amir Solomonica
1University Hospital, London Health Sciences Centre, 339 Windermere Road, London, ON, Canada N6A 5A5. rodrigobagur@yahoo.com.
Rotational atherectomy (RA) using smaller burrs is feasible and achieves high success rates. The study found that large sheaths and catheters are often overused, even with smaller burrs, suggesting a shift towards 6 Fr guide catheters for complex procedures.
Area of Science:
- Cardiology
- Interventional Cardiology
- Vascular Surgery
Background:
- Rotational atherectomy (RA) traditionally uses large guide catheters (≥7 Fr) for large burrs (≥1.75 mm).
- Smaller sheath and catheter sizes are associated with reduced access-site complications.
- This study investigated the feasibility of RA with smaller burrs and smaller sheath catheters.
Purpose of the Study:
- To assess the feasibility of performing rotational atherectomy (RA) using smaller burrs.
- To evaluate the use of smaller-sized sheath catheters in conjunction with smaller RA burrs.
- To analyze procedural outcomes and complications associated with different burr sizes in RA.
Main Methods:
- A retrospective analysis of 220 RA procedures performed between January 2011 and July 2017.
- Comparison of 162 patients (small-burr group, ≤1.5 mm) with 58 patients (large-burr group, >1.5 mm).
- Evaluation of clinical, procedural, safety, and feasibility data, including sheath size, catheter size, and access site.
Main Results:
- The small-burr group (≤1.5 mm) showed a high procedural success rate (93%) compared to the large-burr group (100%).
- Smaller sheath sizes (>6 Fr) were used less frequently in the small-burr group (56.0%) versus the large-burr group (89.5%).
- Radial access was more common in the small-burr group (33%) compared to the large-burr group (17%).
Conclusions:
- Rotational atherectomy (RA) can be successfully performed with smaller burrs, achieving high success rates.
- Overuse of large sheaths and catheters for small burrs was observed, indicating potential for optimization.
- Findings support the use of 6 Fr guide catheters, facilitating radial access for complex interventions.
Related Concept Videos
Cell Size
Surface Area
Cells can take in nutrients and water via diffusion through the plasma membrane itself or through specific channels in the membrane. The area of the membrane surrounding...
Brick Sizes
Modular bricks are the most common type and are sized to include the mortar joint, which is essential for...
Genome Size and the Evolution of New Genes
Genome Size and the Evolution of New Genes
Maximum Size of Aggregate
Sample Size Calculation
The sample size for the given experiment or sampling effort is fundamental to any study design. Sample size decides the number of...