Conversion of computational human phantoms into DICOM-RT for normal tissue dose assessment in radiotherapy patients
Keith T Griffin1, Matthew M Mille1, Christopher Pelletier2
1Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Rockville, MD 20850, United States of America.
Abstract:
Radiotherapy (RT) treatment planning systems (TPS) are designed for the fast calculation of dose to the tumor bed and nearby organs at risk using x-ray computed tomography (CT) images. However, CT images for a patient are typically available for only a small portion of the body, and in some cases, such as for retrospective epidemiological studies, no images may be available at all. When dose to organs that lie out-of-scan must be estimated, a convenient alternative for the unknown patient anatomy is to use a matching whole-body computational phantom as a surrogate. The purpose of the current work is to connect such computational phantoms to commercial RT TPS for retrospective organ dose estimation. A custom software with graphical user interface (GUI), called the DICOM-RT Generator, was developed in MATLAB to convert voxel computational phantoms into the digital imaging and communications in medicine radiotherapy (DICOM-RT) format, compatible with commercial TPS. DICOM CT image sets for the phantoms are created via a density-to-Hounsfield unit (HU) conversion curve. Accompanying structure sets containing the organ contours are automatically generated by tracing binary masks of user-specified organs on each phantom CT slice. The software was tested on a library of body size-dependent phantoms, the International Commission on Radiological Protection reference phantoms, and a canine voxel phantom, taking only a few minutes per conversion. The resulting DICOM-RT files were tested on several commercial TPS. As an example application, a library of converted phantoms was used to estimate organ doses for members of the National Wilms Tumor Study (NWTS) cohort. The converted phantom library, in DICOM format, and a standalone MATLAB-compiled executable of the DICOM-RT Generator are available for others to use for research purposes (http://ncidose.cancer.gov).
More Related Videos
Related Concept Videos
Drug Dosing: Geriatric Patients
Drug Dosing: Obese Patients
Gene Conversion
Gene Conversion
Conversion of Units
The first step in the unit conversion is to list the given units and the units required...
Variation: Normal Distribution, Range, and Standard Deviation