Quantitative Computed Tomography (QCT) of the Distal Forearm in Men Using a Spiral Whole-Body CT Scanner -
Birgit C Hanusch1, Stephen P Tuck2, Babitha Mekkayil1
1The James Cook University Hospital, Middlesbrough, United Kingdom.
Abstract:
The Mr F study investigates the pathogenesis of low trauma distal forearm fractures in men and includes volumetric bone mineral density (vBMD) measurements at the ultradistal forearm as there are no current data. A standard 64 slice CT scanner was used to determine if it was possible to adapt the existing Mindways quantitative computed tomography Pro software for measuring vBMD values at the hip and spine sites. For calculation of intra- and interobserver reliability 40 forearm scans out of the 300 available were chosen randomly. The images were analyzed using the Slice Pick module and Bone Investigational Toolkit. The 4% length of the radius was chosen by measuring the length of the radius from the scaphoid fossa distally to the radial head. The acquired image then underwent extraction, isolation, rotation, and selection of region of interest in order to generate a report on vBMD. A cross-sectional image was created to allow the generation of data on the cortical and trabecular components separately. Repeat analyses were undertaken by 3 independent observers who were blinded as to whether the image was from a participant with or without fracture. The images were presented in random order at each time point. The following parameters were recorded: cortical cross sectional area, total vBMD, trabecular vBMD, and cortical vBMD (CvBMD). Data were analyzed by calculating intraclass correlation coefficients for intra- and interobserver reliability. The lowest values occurred at the CvBMD with intraobserver reliability of 0.92 (95% confidence interval [CI] of 0.86-0.96) and interobserver reliability of 0.92 (95% CI 0.89-0.96). All other parameters had reliability values between 0.97 and 0.99 with tighter 95% CI than for CvBMD. The method of adapting the Mindways Pro software using a standard CT to produce vBMD and structural data at the ultradistal radius is reliable.
More Related Videos
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Reliability and Validity
Muscles that Move the Forearm
Forearm Flexors
The biceps brachii, brachialis, and brachioradialis are forearm flexors. The biceps brachii is made up of two heads. Its long head originates at the supraglenoid tubercle of the scapula, whereas that of the short head is...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...