Related Experiment Video
Updated: Jan 23, 2026

In vitro Biofilm Formation in an 8-well Chamber Slide
Published on: January 20, 2011
Classification and Temporal Variability in Urinary 8-oxodG and 8-oxoGuo: Analysis by UHPLC-MS/MS
Ziqi Li1,2, Yuan Yao1,2, Yanfei Zhang1,2
1Centers for Water and Health, Key Laboratory of Public Health Safety, Ministry of Education, Fudan University, Shanghai, 200032, China.
Abstract:
Oxidative stress damage has been found to be associated with exposure of children to environmental pollutants, but there are few data on the variability of urinary oxidative stress biomarkers and the accuracy of biomarker concentration classification. We performed a longitudinal study in Chinese school-aged children to investigate the variability of urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG) and 8-oxo-7,8-dihydroguanosine (8-oxoGuo) concentrations and the ability of a single first morning urine sample to assess accuracy and sensitivity of biomarkers concentration classification. After adjusting for both creatinine and specific gravity, we characterized the distribution and reproducibility of repeated measurement of 8-oxodG and 8-oxoGuo by using intraclass correlation coefficients (ICCs) derived from linear mixed model and performed surrogate category analyses to determine whether a single spot sample could accurately classify 8-oxodG and 8-oxoGuo levels. Results indicated that the geometric mean (GM) concentrations of 8-oxodG and 8-oxoGuo were 3.865 ng/mL and 5.725 ng/mL, respectively. High variability of 8-oxodG and 8-oxoGuo was observed in the single spot first morning urine sample (ICC = 0.25 and 0.18, respectively). Three repeated urinary specimens achieved sensitivity of 0.87 for 8-oxodG and 0.83 for 8-oxoGuo in low tertile and sensitivity of 0.78 in high tertile. But classification in medium tertile was less accurate for both 8-oxodG and 8-oxoGuo. In conclusion, high variability of urinary 8-oxodG and 8-oxoGuo levels results in repeated samplings needed for accurate classification.
Related Concept Videos
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Classification of Titrimetric Analysis Based on Reaction Types
Titrations between an acid and a base lead to neutralization reactions that form...
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...
Variables Affecting Phosphorescence and Fluorescence
Classification of Neurotransmitters
Classification of Leukocytes
Neutrophils are the most abundant type of granular leukocytes, comprising 50-70% of all leukocytes. They feature small, evenly distributed granules and a...

