Related Experiment Video
Updated: Jan 23, 2026

High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis
Published on: December 22, 2015
Broadband Optical Cavity Mode Measurements at Hz-Level Precision With a Comb-Based VIPA Spectrometer
Grzegorz Kowzan1, Dominik Charczun2, Agata Cygan2
1Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Toruń, Ul. Grudziadzka 5, 87-100, Toruń, Poland. gkowzan@fizyka.umk.pl.
Abstract:
Optical frequency comb spectrometers open up new avenues of investigation into molecular structure and dynamics thanks to their accuracy, sensitivity and broadband, high-speed operation. We combine broadband direct frequency comb spectroscopy with a dispersive spectrometer providing single-spectrum acquisition time of a few tens of milliseconds and high spectral resolution. We interleave a few tens of such comb-resolved spectra to obtain profiles of 14-kHz wide cavity resonances and determine their positions with precision of a few hertz. To the best of our knowledge, these are the most precise and highest resolution spectral measurements performed with a broadband spectrometer, either comb-based or non-comb-based. This result pushes the limits of broadband comb-based spectroscopy to Hz-level regime. As a demonstration of these capabilities, we perform simultaneous cavity-enhanced measurements of molecular absorption and dispersion, deriving the gas spectra from cavity mode widths and positions. Such approach is particularly important for gas metrology and was made possible by the Hz-level resolution of the system. The presented method should be especially applicable to monitoring of chemical kinetics in, for example, plasma discharges or measurements of narrow resonances in cold atoms and molecules.
Related Concept Videos
Uncertainty in Measurement: Accuracy and Precision
IR Spectrometers
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated....
Ordinal Level of Measurement
Data measured using an ordinal scale are similar to nominal scale data, but there is one major difference. The ordinal scale data can be ordered. An example of ordinal scale data is a list of the top five national parks...
Interval Level of Measurement
Data measured using the interval scale are similar to ordinal level data because they have a definite arrangement. However, in the interval level of measurement, the differences between data values are meaningful even though the data does not have a starting point.
Temperature is measured using the interval scale. It is measurable data, and the difference between...
Nominal Level of Measurement
The data that cannot be measured but can be grouped into categories fall under the nominal level of measurement. Data that is measured using a nominal...

