Related Experiment Video
Updated: Jan 23, 2026

Simple Continuous Glucose Monitoring in Freely Moving Mice
Published on: February 24, 2023
Continuous glucose monitoring targets in type 1 diabetes pregnancy: every 5% time in range matters
1Norwich Medical School, University of East Anglia, Floor 2, Bob Champion Research and Education Building, Norwich, NR4 7UQ, UK. helen.murphy@uea.ac.uk.
Abstract:
With randomised trial data confirming that continuous glucose monitoring (CGM) is associated with improvements in maternal glucose control and neonatal health outcomes, CGM is increasingly used in antenatal care. Across pregnancy, the ambition is to increase the CGM time in range (TIR), while reducing time above range (TAR), time below range (TBR) and glycaemic variability measures. Pregnant women with type 1 diabetes currently spend, on average, 50% (12 h), 55% (13 h) and 60% (14 h) in the target range of 3.5-7.8 mmol/l (63-140 mg/dl) during the first, second and third trimesters, respectively. Hyperglycaemia, as measured by TAR, reduces from 40% (10 h) to 33% (8 h) during the first to third trimester. A TIR of >70% (16 h, 48 min) and a TAR of <25% (6 h) is achieved only in the final weeks of pregnancy. CGM TBR data are particularly sensor dependent, but regardless of the threshold used for individual patients, spending ≥4% of time (1 h) below 3.5 mmol/l or ≥1% of time (15 min) below 3.0 mmol/l is not recommended. While maternal hyperglycaemia is a well-established risk factor for obstetric and neonatal complications, CGM-based risk factors are emerging. A 5% lower TIR and 5% higher TAR during the second and third trimesters is associated with increased risk of large for gestational age infants, neonatal hypoglycaemia and neonatal intensive care unit admissions. For optimal neonatal outcomes, women and clinicians should aim for a TIR of >70% (16 h, 48 min) and a TAR of <25% (6 h), from as early as possible during pregnancy.
Related Concept Videos
Diabetes Mellitus: Type 2 and Gestational
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Continuous -time Fourier Transform
Basic Continuous Time Signals
The unit step function, denoted u(t), is zero for negative time values and one for positive time values, exhibiting a discontinuity at t=0. This function often represents abrupt changes, such as the step voltage introduced when turning a car's...
Sampling Continuous Time Signal
In the...
Classifying Matter by State

