Anti-drug Antibody Assay Conditions Significantly Impact Assay Screen and Confirmatory Cut-Points
Boris Gorovits1, Ying Wang2, Liang Zhu2
1Pfizer Inc., 1 Burtt Rd, Andover, Massachusetts, 01810, USA. boris.gorovits@pfizer.com.
Abstract:
Assays for the detection and confirmation of anti-drug antibodies (ADA) are commonly used tools for assessing the immunogenicity of drug candidates in both clinical and nonclinical studies. During the development of such assays, it is typical to optimize the assay conditions based on factors such as sensitivity or signal/noise ratio (S/N) and is commonly done using an assay positive control (PC). However, even carefully optimized methods often suffer with problems due to low cut-point factors and failure to distinguish assay "noise" from a true biological response. In this paper, we describe an approach to assay development in which the impacts of assay conditions on the response and variability, both analytical and biological, of drug-naïve samples are tested by way of PC-independent assay condition optimization. Using two ADA methods as model systems, we examine the impact of minimum required dilution, assay reagent (labeled drug) concentrations, incubation time, assay, and wash buffer composition. We find that the choice of assay conditions, particularly the labeled drug concentration, can greatly affect the distribution of naïve sample responses and thus impact screening and confirmatory assay cut-points. In two case studies presented, screening assay cut-point (SCP) varied from 1.38 to 2.20 and 1.04 to 1.20 while the confirmatory assay cut-point (CCP) varied from 58.5 to 95.6% and 26.2 to 16.2% depending on the conditions tested. Some of the conditions produced unacceptably high CCP values. It is proposed that the degree of the observed impact of the assay conditions on SCP and CCP values depends on the compound nature and assay matrix composition and is likely connected with the diversity of interactions between drug protein and matrix components. Because it was also observed that higher assay SCP can associate with a loss of the PC-based assay sensitivity, additional assessment of the assay conditions would be required to determine an overall assay performance acceptability, including assay PC-based sensitivity, drug, and target tolerance characteristics. In conclusion, it is suggested that by assessing performance of treatment-naïve samples at various assay conditions, one can identify potential assay protocols that allow to avoid undesirably low screening (e.g., < 1.2) and confirmatory (e.g., < 25%) cut-points.
More Related Videos
13:59High-Content Screening Assay for the Identification of Antibody-Dependent Cellular Cytotoxicity Modifying Compounds
Published on: August 18, 2023
07:52Detection of Antibodies That Neutralize the Cellular Uptake of Enzyme Replacement Therapies with a Cell-based Assay
Published on: September 10, 2018
Related Concept Videos
Antiasthma Drugs: Mast Cell Stabilizers and Anti-IgE Drugs
Mast cell stabilizers, such as cromolyn (also known as sodium cromoglycate) and nedocromil (Tilade), are effective drugs in asthma management. These stabilizers hinder histamine release by skillfully obstructing the activation of mast cells and other cellular entities. Notably, they navigate this task without...
Drug Control Governance: Regulatory Bodies and Their Impact
Drugs for Treatment of Crohn's Disease in IBD Using Biologic Agents: Anti-TNF
Impact of Groups on Groups
Cut-off Frequency of BJT
Alpha Cut-Off Frequency: Pertinent to the common-base configuration, the alpha cut-off frequency defines the upper-frequency limit at which the current gain, alpha, remains stable. As...
Brick Cutting Techniques
Cut bricks are categorized by size. Bricks cut to half their original length are called half-bats, while those cut to three-fourths their length are known as three-fourth bats.
Special types of...