A Darwood1, J McCanny1, R Kwasnicki2
1Department of Anaesthesia, Imperial College Healthcare NHS Trust, London, UK.
Abstract:
Modern mechanical ventilator technologies broadly consist of digitally-controlled electronic devices and analogue systems driven by compressed gas sources. Drawbacks such as high cost, complex maintenance and the need for cumbersome sources of compressed driving gas hinder adoption in pre-hospital and low-resource environments. We describe the evaluation and testing of a simple, low-cost alternative ventilator that uses a novel pressure-sensing approach and control algorithm. This is designed to provide portable positive-pressure mechanical ventilation at a reduced cost, while autonomously monitoring patient condition and important safety parameters. A prototype ventilator was constructed and evaluated using an anaesthetic test-lung as a patient surrogate. Using a modifiable test-lung and digital pressure sensor, we investigated ventilation pressure waveform circuit leak detection, and compliance and resistance change detection. During intermittent positive-pressure ventilation to the test-lung, the prototype system showed acceptable pressure waveform parameters: all simulated circuit leaks ≥ 6 mm2 in size were detected; compliance changes were detected between 10 ml.cmH2 O-1 , 20 ml.cmH2 O-1 and 50 ml.cmH2 O-1 ; and resistance changes were detected across the available simulated range. These results show this prototype technology has the potential to provide safe emergency ventilation without the use of any complex digital sensors or software while its construction and design enables significant reductions in cost and complexity. The study suggests further work is now justified in progressing the technology to clinical trials.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Factorial Design
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Group Design
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...