Evaluation of Syndesmosis Reduction on CT Scan
Mohamed Elghazy Abdelaziz1,2, Noortje Hagemeijer2,3, Daniel Guss2,4
11 Department of Orthopaedic Surgery, Faculty of Medicine, Mansoura University, Mansoura, Dakahliya, Egypt.
Background:
Computed tomography (CT) imaging has traditionally been considered the gold standard for evaluation of syndesmostic reduction, but there is no uniformly accepted method to assess reduction. The aim of this study was to evaluate the intra- and interobserver reliability of published measurement techniques for evaluation of syndesmotic reduction on weightbearing CT scan (WBCT) in hopes of determining which method is best.
Methods:
Medical records were reviewed to identify patients who underwent operative stabilization of unilateral syndesmotic injuries. Exclusion criteria included patients younger than 18 years, ipsilateral fractures extending to the tibial plafond, any contralateral ankle fracture or syndesmotic injury, and body mass index greater than 40 kg/m2. Twenty eligible patients underwent WBCT evaluation of both ankles at an average of 3 years after syndesmotic fixation. The anatomic accuracy of syndesmotic reduction was evaluated by 2 observers using axial CT images at a level 1 cm proximal to the tibial plafond using 9 previously published radiological measurement techniques. Inter- and intraobserver reliability were assessed for each evaluation method.
Results:
The syndesmotic area calculation showed the highest interobserver reliability (0.96), the highest intraobserver reliability for observer 2 (0.97), and the second highest intraobserver reliability for observer 1 (0.92). Fibular rotation had the second highest interobserver reliability in our results (0.84), with intraobserver reliability of 0.91 and 0.8 for first and second observers, respectively. The intraobserver reliability of the side-by-side method was 0.49 and 0.24 for the first and second observers, respectively, and the interobserver reliability was 0.26.
Conclusion:
Qualitatively assessing syndesmotic reduction via side-by-side comparison with the uninjured ankle had the least intra- and interobserver reliability and should not be relied on to determine syndesmotic reduction quality. In contradistinction, syndesmotic area calculation demonstrated the highest reliability when evaluating syndesmotic reduction, followed by fibular rotation. Given that syndesmotic area measurement techniques are not readily available on standard image viewers, technologically updating image viewers to allow such calculation would make this approach more accessible in clinical practice.
Level Of Evidence:
Level IV, case series.
More Related Videos
10:42In Depth Analyses of LEDs by a Combination of X-ray Computed Tomography CT and Light Microscopy LM Correlated with Scanning Electron Microscopy SEM
Published on: June 16, 2016
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
Related Concept Videos
Oxidation-Reduction Reactions
Leaky Scanning
Block Diagram Reduction
The first step in this process is the identification and relocation of a branch point. A branch point, where a...
Oxymercuration-Reduction of Alkenes
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...