Related Experiment Video
Updated: Jan 23, 2026

Construction and Characterization of External Cavity Diode Lasers for Atomic Physics
Published on: April 24, 2014
Highly sensitive acetylene detection based on multi-pass retro-reflection-cavity-enhanced photoacoustic spectroscopy
Abstract:
In this paper, a multi-pass retro-reflection-cavity-enhanced photoacoustic spectroscopy (PAS) based gas sensor is reported for the first time. The multi-pass retro-reflection-cavity consisted of two right-angle prisms and was designed to reflect the laser beam to pass through the photoacoustic (PA) cell four times, which improved the acetylene (C2H2)-PAS sensor signal level significantly. The optical power of a near-infrared distributed feedback (DFB) diode laser emitting a continuous wave (CW) was amplified to 1000 mW with an erbium-doped fiber amplifier. The background noise was reduced with wavelength modulation spectroscopy (WMS) and 2nd harmonic demodulation techniques. The linear optical power and concentration response of such a PAS sensor were investigated, and the experimental results showed excellent characteristics. When the integration the time of the sensor system was set to 1 s, the minimum detection limit (MDL) for C2H2 detection was 8.17 ppb, which corresponds to a normalized noise equivalent absorption coefficient (NNEA) of 1.84 × 10-8 cm-1W/√Hz. The long-term stability of such a multi-pass retro-reflection-cavity-enhanced PAS based C2H2 sensor was evaluated by an Allan deviation analysis. It was demonstrated that the multi-pass retro-reflection-cavity-enhanced PAS sensor had an excellent stability. An MDL of 600 ppt was achieved when the integration time was set to ~1000 s. It was verified that the method of multi-pass retro-reflection-cavity-enhanced PAS with an amplified laser source improved the sensor performance significantly. If an appropriate cavity design with increasing reflection times is used, the MDL of such a PAS-based sensor can be further improved.
Related Concept Videos
Insertion of Multi-pass Transmembrane Proteins in the RER
The multipass transmembrane proteins are the type IV integral membrane proteins with multiple topogenic sequences determining their spatial arrangement in the ER membrane. Nearly all multipass proteins lack a cleavable signal sequence and use...
Multi-pass Transmembrane Proteins and β-barrels
α-Helix containing multi-pass transmembrane proteins
Multi-pass transmembrane proteins such as...
First Pass Effect
Depending on the route of administration, drugs can be metabolized in the liver, intestine, lungs, and vasculature. Orally administered drugs are first absorbed through the...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Local Anesthetics: Differential Sensitivity of Nerve Fibers
BJT Amplifiers
In BJT amplifier configurations, particularly in common-emitter setups, the transistor's role...

