Interictal epileptogenic zone localization in patients with focal epilepsy using electric source imaging and directed
Ana Coito1, Silke Biethahn1, Janina Tepperberg1
1Department of Neurology Cantonal Hospital Aarau Aarau Switzerland.
Objective:
Electrical source imaging (ESI) is used increasingly to estimate the epileptogenic zone (EZ) in patients with epilepsy. Directed functional connectivity (DFC) coupled to ESI helps to better characterize epileptic networks, but studies on interictal activity have relied on high-density recordings. We investigated the accuracy of ESI and DFC for localizing the EZ, based on low-density clinical electroencephalography (EEG).
Methods:
We selected patients with the following: (a) focal epilepsy, (b) interictal spikes on standard EEG, (c) either a focal structural lesion concordant with the electroclinical semiology or good postoperative outcome. In 34 patients (20 temporal lobe epilepsy [TLE], 14 extra-TLE [ETLE]), we marked interictal spikes and estimated the cortical activity during each spike in 82 cortical regions using a patient-specific head model and distributed linear inverse solution. DFC between brain regions was computed using Granger-causal modeling followed by network topologic measures. The concordance with the presumed EZ at the sublobar level was computed using the epileptogenic lesion or the resected area in postoperative seizure-free patients.
Results:
ESI, summed outflow, and efficiency were concordant with the presumed EZ in 76% of the patients, whereas the clustering coefficient and betweenness centrality were concordant in 70% of patients. There was no significant difference between ESI and connectivity measures. In all measures, patients with TLE had a significantly higher (P < 0.05) concordance with the presumed EZ than patients with with ETLE. The brain volume accepted for concordance was significantly larger in TLE.
Significance:
ESI and DFC derived from low-density EEG can reliably estimate the EZ from interictal spikes. Connectivity measures were not superior to ESI for EZ localization during interictal spikes, but the current validation of the localization of connectivity measure is promising for other applications.
More Related Videos
10:22Interictal High Frequency Oscillations Detected with Simultaneous Magnetoencephalography and Electroencephalography as Biomarker of Pediatric Epilepsy
Published on: December 6, 2016
09:57Author Spotlight: Advancing Pediatric Epilepsy Surgery in Children Through Novel Biomarkers and Enhanced Localization
Published on: September 20, 2024
Related Concept Videos
Functions of Connective Tissues
Hard connective tissues, such as bones and cartilage, provide structure and support to the body.
Sources and Properties of Electric Charge
Most atoms additionally constitute another fundamental particle, the neutron. It carries no electrical charge. A...
Hybrid Zones
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Transition Zone
Dietary Connections