Related Experiment Video
Updated: Jan 23, 2026

Robotic Cochlear Implantation for Direct Cochlear Access
Published on: June 16, 2022
Workflow assessment as a preclinical development tool : Surgical process models of three techniques for minimally
Samuel Müller1, Lüder A Kahrs2, Johannes Gaa2
1Leibniz Universität Hannover Institute of Mechatronic Systems, 30167, Hannover, Germany. samuel.mueller@imes.uni-hannover.de.
Purpose:
Minimally invasive cochlear implant surgery is a challenging procedure due to high demands on accuracy. For clinical success, an according assistance system has to compete against the traditional approach in terms of risk, operating time and cost. It has not yet been determined what kind of system is the most suited. The purpose of this study is a proof of concept of surgical process modeling as a preclinical development tool and the comparison of workflow concepts for this new approach.
Methods:
Three preclinical systems (two stereotactic and one robotic) for minimally invasive cochlear implant surgery are compared using the method of surgical process modeling. All three systems were successfully tested with ex vivo human specimen to create minimally invasive surgical access to the cochlea. Those systems where chosen for comparison, because they represent three diverse approaches with different corresponding workflows for the same intervention. The experiments were used to create a process model for each system by recording the interventions.
Results:
All three conceptual systems developed by our group have shown their eligibility. The recorded process models provide a convenient method for direct comparison. Reduction in the surgical time has a higher impact on the process, than time that is needed for setting up a system beforehand. The stereotactic approaches have little preparation effort and are low cost in terms of hardware compared to the robotic approach, which in return is beneficial in terms of workload reduction for the surgeon.
Conclusion:
Surgical process modeling is suitable for comparison of different assistant systems for minimally invasive cochlear implantation. The benefit of reduced trauma, compared to the traditional mastoidectomy, can now be assessed with consideration of the workflow of each technique. The process models enable an assessment in the regard of surgical time and workload.
Related Concept Videos
Preclinical Development: Overview
Steps in the Modeling Process
Attention is the first necessary component for observational learning. It involves focusing on what the model is doing and saying. For example, if you decide to take a drawing class to enhance your skills, you need to pay close attention to the instructor's words and hand movements. The characteristics of the model significantly...
Role of Communication in the Nursing Process I: Assessment and Diagnosis
The nursing process considers the patient's emotional and physical well-being. The process can be repeated or stopped at any point if judged essential. Assessment is the first step in the nursing...
Nursing Process for Patient and Caregiver Teaching I: Assessment and Diagnosis
It is critical to determine the patient's learning needs during the assessment. Determination of learning needs compounds data...
Sustainable Development
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...

