A Monte Carlo study on dose perturbation due to dental restorations in a 15 MV photon beam
Mona Azizi1, Ali Asghar Mowlavi2, Mehdi Ghorbani3
1Department of Physics, School of Sciences, Hakim Sabzevari University, Sabzevar, Iran.
Aim:
The main purpose of this study is to evaluate the effect of dose perturbation due to common dental restoration materials in the head and neck radiotherapy with a 15 MV external photon beam.
Setting And Design:
Teeth with three dental restorations such as tooth filled with Amalgam, Ni-Cr alloy, and Ceramco were simulated by MCNPX Monte Carlo code. In this simulation, the dental materials were exposed by a 15 MV photon beam from a Siemens Primus linac, inside a water phantom.
Materials And Methods:
A Siemens Primus linear accelerator and a phantom including: tooth only, tooth with Amalgam, tooth with Ni-Cr alloy, and tooth with Ceramco were simulated by MCNPX Monte Carlo code, separately. The percentage dose change was evaluated relative to dose in water versus depth for these samples on the beam's central axis. The absolute dose by prescription of 100 cGy dose in water phantom at 3.0 cm depth was calculated for water, tooth, tooth with Amalgam, tooth with Ni-Cr alloy, and tooth with Ceramco.
Results:
The maximum percentage dose change is related to tooth with Ni-Cr alloy, tooth, tooth with Ceramco, and tooth with Amalgam with amounts of 7.73%, 6.95%, 4.7%, and 3.06% relative to water at 0.75 cm depth, respectively. When 100.0 cGy dose was prescribed at 3.1 cm, the maximum absolute dose was 201.0% in the presence of tooth with Ni-Cr alloy at 0.75 cm.
Conclusion:
Introduction of the compositions of dental restorations can improve the accuracy of dosimetric calculations in treatment planning and protect the healthy tissues surrounding teeth from a considerable overdose.
Related Concept Videos
Restorative Care
Bioavailability Study Design: Single Versus Multiple Dose Studies
Other Nuclides: 31P, 19F, 15N NMR
While fluorine-19 and phosphorous-31 have high natural abundances (100%) and positive gyromagnetic ratios, nitrogen-15 has a low natural abundance and a negative gyromagnetic ratio. However, nitrogen-15 is still preferred over nitrogen-14 (which has a...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses