Laurent Gauthier-Fournet1, Franck Penin2, Samuel Arba Mosquera2
1Helios Ophtalmologie, St. Jean-de-Luz, France.
Purpose:
To evaluate refractive and visual outcomes of laser-assisted in situ keratomileusis (LASIK) to treat high hyperopia using an aberration-neutral profile and large ablation zone.
Methods:
This was a retrospective, consecutive observational case series at Helios Ophtalmologie, St. Jean-de-Luz, France. One hundred forty-six consecutive eyes of 77 patients who underwent LASIK with mechanical microkeratome to correct hyperopia with correction in the maximum hyperopic meridian strictly higher than +5 D (mean + 6.6 ± 1.0 D) were included. Procedures were performed with an Amaris 750S excimer laser (Schwind eye-tech-solutions GmbH, Kleinostheim, Germany) using an aberration-neutral profile, a 6.7 ± 0.1 mm optical zone, and a 9.2 ± 0.1 mm total ablation zone. Refractive results, predictability, safety, and efficacy were evaluated at 6 months postoperatively.
Results:
At 6 months postsurgery, the mean manifest refraction spherical equivalent was -0.06 ± 0.83 D and the mean cylinder was 0.42 ± 0.35 D. Sixty-six percent of eyes were within ±0.50 D of the attempted spherical equivalent correction. Six months postoperatively, 60% of eyes achieved an uncorrected distance visual acuity of 20/20 or better. Ten percent of eyes lost 1 line of corrected distance visual acuity and 4% gained a line. No eyes lost more than 2 Snellen lines of corrected distance visual acuity at any follow-up.
Conclusions:
High hyperopia correction with LASIK using an aberration-neutral profile and large ablation zone provides good efficacy, safety, predictability, and visual outcomes.