Immunophenotyping of Murine Precursor B-Cell Leukemia/Lymphoma: A Comparison of Immunohistochemistry and Flow

Laura J Janke1, Charles G Mullighan1, Jinjun Dang1

  • 1Department of Pathology, St. Jude Children's Research Hospital, Memphis, TN, USA.

In humans and in mouse models, precursor B-cell lymphoblastic leukemia (B-ALL)/lymphoblastic lymphoma (B-LBL) can be classified as either the pro-B or pre-B subtype. This is based on the expression of antigens associated with the pro-B and pre-B stages of B-cell development. Antigenic markers can be detected by flow cytometry or immunohistochemistry (IHC), but no comparison of results from these techniques has been reported for murine B-ALL/LBL. In our analysis of 30 cases induced by chemical or viral mutagenesis on a WT or Pax5+/- background, 18 (60%) were diagnosed as pro-B by both flow cytometry and IHC. Discordant results were found for 12 (40%); 6 were designated pro-B by IHC and pre-B by flow cytometry and the reverse for the remaining 6 cases. Discordance occurred because different markers were used to define the pro-B-to-pre-B transition by IHC vs flow cytometry. IHC expression of cytoplasmic IgM (μIgM) defined the pre-B stage, whereas the common practice of using CD25 as a surrogate marker in flow cytometry was employed here. These results show that CD25 and μIgM are not always concurrently expressed in B-ALL/LBL, in contrast to normal B-cell development. Therefore, when subtyping B-ALL/LBL in mice, an IHC panel of B220, PAX5, TdT, c-Kit/CD117, CD43, IgM, and ΚLC should be considered. For flow cytometry, cytoplasmic IgM may be an appropriate marker in conjunction with the surface markers B220, CD19, CD43, c-Kit/CD117, BP-1, and CD25.

Related Concept Videos

Flow Cytometry01:23

Flow Cytometry

The development of flow cytometry techniques began in 1934 with initial attempts by Andrew Moldavan, a bacteriologist who counted the cells in a flowing capillary system. Moldavan pumped cells through a capillary tube focused under a microscope for visualization. The invention of photometry allowed the measurement of differentially-stained cells, and Louis Kamentsky developed the first multiparameter flow cytometer in 1965 to identify and count the cancer cells in cervical tissue specimens.
In...
15.9K
The Sense of Self: Reflected Self-Appraisal and Social Comparison02:57

The Sense of Self: Reflected Self-Appraisal and Social Comparison

According to Charles Cooley, we base our image on what we think other people see (Cooley 1902). We imagine how we must appear to others, then react to this speculation. We don certain clothes, prepare our hair in a particular manner, wear makeup, use cologne, and the like—all with the notion that our presentation of ourselves is going to affect how others perceive us. We expect a certain reaction, and, if lucky, we get the one we desire and feel good about it. But more than that, Cooley...
55.5K
Immunocytochemistry and Immunohistochemistry01:22

Immunocytochemistry and Immunohistochemistry

Immunocytochemistry (ICC) and immunohistochemistry (IHC) are techniques that use antibodies to check for specific proteins or antigens in a sample. The technique was first published by Albert Coons in 1941 to detect the presence of pneumococcal antigen in tissue sections from mice infected with Pneumococcus. Immunocytochemistry helps localization of proteins or antigens in individual cells like blood cells, stem cells, etc., while immunohistochemistry does the same for tissue samples.
These...
13.5K
Multiple Comparison Tests01:13

Multiple Comparison Tests

Multiple comparison test, abbreviated as MCT, is a post hoc analysis generally performed after comparing multiple samples with one or more tests. An MCT will help identify a significantly different sample among multiple samples or a factor among multiple factors.
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
4.4K
Molecular Comparison of Gases, Liquids, and Solids02:26

Molecular Comparison of Gases, Liquids, and Solids

Particles in a solid are tightly packed together (fixed shape) and often arranged in a regular pattern; in a liquid, they are close together with no regular arrangement (no fixed shape); in a gas, they are far apart with no regular arrangement (no fixed shape). Particles in a solid vibrate about fixed positions (cannot flow) and do not generally move in relation to one another; in a liquid, they move past each other (can flow) but remain in essentially constant contact; in a gas, they move...
54.3K
Mitochondrial Precursor Proteins01:39

Mitochondrial Precursor Proteins

Mitochondrial precursors are partially unfolded or loosely folded polypeptide chains. Newly synthesized precursors are inhibited from spontaneously folding into their native conformation by the cytosolic chaperones, heat shock proteins 70 (Hsp70), and mitochondrial import stimulation factors (MSFs). Precursors bound to MSFs are guided to the TOM70-TOM37 receptors, while precursors bound to Hsp70  chaperones are targetted to TOM20-TOM22 receptor complexes.
Most of the mitochondrial...
3.6K