Automated continuous-flow in-syringe dispersive liquid-liquid microextraction of mono-nitrophenols from large sample
K Fikarová1, B Horstkotte1, H Sklenářová1
1Charles University, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Akademika Heyrovského 1203, 500 05, Hradec Králové, Czech Republic.
Abstract:
Continuous magnetic stirring-assisted dispersive liquid-liquid extraction followed by dispersive backextraction as a novel pre-treatment technique for adaptable and milliliter volumes of environmental samples has been developed. The procedure was automated using the technique "Lab-In-Syringe". The void of the automated syringe pump was used as size-adaptable extraction chamber. By a flow channel in the syringe piston, continuous flow through the syringe void was enabled. 1-Octanol was used as an extractant and dispersed by the action of a magnetic stirring bar, which was placed inside the syringe and driven by an external rotating magnetic field. Extract washing and dispersive backextraction in an alkaline aqueous acceptor phase were carried out after the preceding extraction from the acidified water sample. Analyte determination was achieved using multivariate spectrum analysis. The method was applied to determine priority pollutants, mono-nitrophenols, in surface water and enabled to reach limits of detection for o-, m-, p-nitrophenol (λ = 418, 390, 400 nm, respectively) of 0.14, 0.26, and 0.02 μmol L-1 (19.5, 36.2, and 2.8 μg L-1), respectively. Under optimized conditions, relative standard deviations were generally less than 5% and enrichment factors of o-, m-, p-nitrophenol 19, 25, and 21, respectively, were achieved using sample volumes of up to 24 mL. Average recoveries of o-, m-, p-nitrophenol from spiked surface water were 94, 82, and 92%, respectively. The concentration of humic acid was found 6-times reduced with respect to the analyte. In addition, adding spectral background modeling allowed nitrophenol determination with precision adequate for routine analysis.
More Related Videos
10:47High-throughput, Automated Extraction of DNA and RNA from Clinical Samples using TruTip Technology on Common Liquid Handling Robots
Published on: June 11, 2013
05:26A Standardized Liquid Biopsy Preanalytical Protocol for Downstream Circulating-Free DNA Applications
Published on: September 16, 2022
Related Concept Videos
Molecular Comparison of Gases, Liquids, and Solids
Rise of Liquid in a Capillary Tube
Deriving the Speed of Sound in a Liquid
The speed of sound in fluids can be derived by considering a mechanical wave...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
Speed of Sound in Solids and Liquids