Miniaturized analytical platform for cocaine detection in oral fluids by MicroNIR/Chemometrics
Roberta Risoluti1, Simona Pichini2, Roberta Pacifici2
1Department of Chemistry -"Sapienza" University of Rome p.le A.Moro 5, 00185, Rome, Italy.
Abstract:
In the field of forensic toxicology, the use of non-destructive and easy-to-use analytical techniques deserves remarkable attention, especially in those situations involving public health and security. In addition, the miniaturization and portability of one-touch devices for the detection of specific threats is required more and more. In this study, a novel on-site MicroNIR/Chemometric platform was developed to perform a real-time prediction of cocaine and its metabolites in non pre-treated oral fluid. Simulated oral fluids were prepared in water in order to calibrate the instrumental response and the matrix effect was consequently evaluated by processing spiked oral fluids collected from volunteers. The procedure was optimized using a proper experimental design taking into account the equilibrium between cocaine and benzoylecgonine in the range 10-100 ng-ml and validated by comparing results with the reference official method (GC-MS). The developed method was statistically able to discriminate oral fluid samples containing cocaine from 10 to 100 ng/ml and demonstrated to be not affected by the variability of the matrix as all the blank samples of different volunteers (smokers and non smokers, assuming caffeine, sugars, chewing-gum or alcohol) as well as spiked oral fluids were correctly predicted by the model. In addition, results from six real samples confirmed the feasibility of the miniaturized platform to provide a correct identification of cocaine abuse and to propose the MicroNIR as innovative personal screening system to prevent accidents and in cases involving workplace surveillance.
Related Concept Videos
CNS Stimulants: Cocaine, Amphetamines and Cannabinoids
Development of Analytical Methods
Oral Cavity
Teeth: The teeth are the hardest structures in our bodies. Humans have two sets of teeth throughout their lifetime: deciduous (baby) teeth and permanent teeth. Each tooth consists of several parts: the crown (visible part), the root (embedded in the jaw), enamel (hard outer...
Analyte Adsorption and Distribution
Jung's Analytical Theory
Graphical and Analytic Representation of Sinusoids
The first step is measuring the peak-to-peak value, which is twice the amplitude of the sinusoid. This provides information about the maximum voltage swing of the waveform.
Secondly, the period and angular frequency are determined. The period is the time taken for one complete cycle of the waveform, while...


