Related Experiment Video
Updated: Jan 23, 2026

Cox-Maze IV Procedure Concomitant with Valvular Surgery In Situs Inversus Dextrocardia: A Single-Center Experience in China
Published on: February 11, 2022
The first four cases of successful NeoChord procedure in mainland China
Li-Han Wang1, Zhao-Xia Pu1, Min-Jian Kong1
1Cardiovascular Department, the Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310009, China.
Background:
Transapical off-pump NeoChord procedure is a novel minimally invasive surgical repair of degenerative mitral regurgitation (MR). Here, we report the first four cases of NeoChord procedure in patients with mitral valve prolapse in mainland China.
Methods:
Four patients, aged 86, 84, 80 and 60 years, with severe MR due to posterior middle scallop prolapse (P2), underwent transapical off-pump artificial chordae implantation on April 9 and 10, 2019. The procedure was performed by left mini-thoracotomy under general anaesthesia and guided by 2D and 3D dimensional transoesophageal echocardiography (TEE).
Results:
Mitral valve repair via NeoChord procedure was successfully performed with implantation of 3 artificial chordae in the first patient and 3, 2, and 3 artificial chordae in the following patients, respectively. Intraoperative TEE and pre-discharge transthoracic echocardiography (TTE) showed only mild to moderate MR of these four patients and no postoperative complications were noted. There were no changes of TTE finding between one-month follow-up and pre-discharge.
Conclusion:
The successful NeoChord procedures in four Chinese indicate that the valve repair using the NeoChord system for Chinese population is feasible.
Related Concept Videos
Ecological Succession
Blind Procedures
Handwashing II: Pre-procedure and Initial Procedure Steps
The hand washing procedure itself includes the following steps. First, cover cuts, if any, on hands with a waterproof dressing. Cuts and abrasions can become contaminated with bacteria hindering the ability to clean the area thoroughly. In addition, repeated hand washing can worsen an injury. The nails must be short and clean, without nail...
Handwashing III: During the Procedure and Post-Procedure Steps
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Suctioning II: Procedure