Abstract:
Functional near-infrared spectroscopy (fNIRS) is a noninvasive brain imaging technique to measure evoked changes in cerebral blood oxygenation. In many evoked-task studies, the analysis of fNIRS experiments is based on a temporal linear regression model, which includes block-averaging, deconvolution, and canonical analysis models. The statistical parameters of this model are then spatially mapped across fNIRS measurement channels to infer brain activity. The trade-offs in sensitivity and specificity of using variations of canonical or deconvolution/block-average models are unclear. We quantitatively investigate how the choice of basis set for the regression linear model affects the sensitivity and specificity of fNIRS analysis in the presence of variability or systematic bias in underlying evoked response. For statistical parametric mapping of amplitude-based hypotheses, we conclude that these models are fairly insensitive to the parameters of the regression basis for task durations and we report the highest sensitivity-specificity results using a low degree-of-freedom canonical model under these conditions. For shorter duration task ( ), the signal-to-noise ratio of the data is also important in this decision and we find that deconvolution or block-averaging models outperform the canonical models at high signal-to-noise ratio but not at lower levels.
More Related Videos
10:25Construction of Models for Nondestructive Prediction of Ingredient Contents in Blueberries by Near-infrared Spectroscopy Based on HPLC Measurements
Published on: June 28, 2016
05:25Author Spotlight: Assessing Brain Activity in Robotic-Assisted Lower Limb Rehabilitation Using fNIRS
Published on: June 7, 2024
Related Concept Videos
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Non-Canonical Wnt Signaling Pathways
Linear Circuits