Retinal and Choroidal Thickness Changes in Populations with Helicobacter pylori Infection by Swept-Source Optical Coherence Tomography
Published on: November 1, 2024
Comparative analysis of 2 swept-source optical coherence tomography biometers.
Francesco Sabatino1, Francesco Matarazzo1, Oliver Findl2
1Moorfields Eye Hospital NHS Foundation Trust, London, United Kingdom.
The Argos swept-source optical coherence tomography (SS-OCT) biometer shows good agreement and repeatability with the IOLMaster 700 for ocular measurements. This comparison is crucial for accurate refractive surgery planning.
Area of Science:
- Ophthalmology
- Biomedical Engineering
- Optical Coherence Tomography
Background:
- Accurate biometry is essential for refractive outcomes in cataract surgery.
- Swept-source optical coherence tomography (SS-OCT) offers advanced capabilities for ocular measurements.
Purpose of the Study:
- To compare the agreement, repeatability, and correlation of ocular measurements between two SS-OCT biometers: the IOLMaster 700 (reference) and the Argos (new).
- To evaluate the performance of the Argos biometer against a established standard.
Main Methods:
- Retrospective case series involving 112 patients (218 eyes).
- Measurements included axial length, keratometry, central corneal thickness, anterior chamber depth, lens thickness, and corneal diameter.
- Bland-Altman analysis for agreement, Cronbach's alpha for internal consistency, and intraclass correlation coefficient (ICC) for repeatability were used.
Main Results:
- Statistically significant differences were found between biometers for most parameters (P < .05), except axial length.
- Very high correlation was observed for all parameters except corneal diameter.
- Excellent internal consistency and intraoperator repeatability (ICC) were demonstrated for both biometers.
Conclusions:
- The Argos SS-OCT biometer demonstrates good agreement and repeatability compared to the IOLMaster 700.
- The findings support the clinical utility of the Argos biometer for ophthalmic measurements.
More Related Videos
11:21Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography
Published on: January 15, 2013
03:35Determining Gender-Based Differences in Retinal and Choroidal Thickness in Underweight Individuals via Swept-Source Optical Coherence Tomography
Published on: December 1, 2023
Related Concept Videos
Comparing the Survival Analysis of Two or More Groups
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Nodal Analysis with Voltage Sources
Consider a circuit that contains four resistors and two voltage sources, as shown in Figure 1. One of these voltage sources is connected between a...
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Comparing Experimental Results: Student's t-Test
Comparative Excretory Systems