Related Experiment Video
Updated: Jan 23, 2026

Optimized Analysis of In Vivo and In Vitro Hepatic Steatosis
Published on: March 11, 2017
Assessment of hepatic steatosis by using attenuation imaging: a quantitative, easy-to-perform ultrasound technique
Jae Seok Bae1,2, Dong Ho Lee3,4, Jae Young Lee1,2,5
1Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.
Objectives:
To evaluate the diagnostic performance of attenuation imaging (ATI) in the detection of hepatic steatosis compared with a histopathology gold standard.
Methods:
We prospectively enrolled 108 consecutive patients (35 males; median age, 54.0 years) who underwent percutaneous liver biopsy for evaluation of diffuse liver disease between January 2018 and November 2018 in a tertiary academic center. Grayscale ultrasound examination with ATI was performed just before biopsy, and an attenuation coefficient (AC) was obtained from each patient. The degree of hepatic steatosis, fibrosis stage, and necroinflammatory activity were assessed on histopathologic examination. The significant factor associated with the AC was found by a linear regression analysis, and the diagnostic performance of the AC for the classification into each hepatic steatosis stage was evaluated by receiver operating characteristic (ROC) analysis.
Results:
The distribution of hepatic steatosis grade on histopathology was 53/11/22/16/6 for none/mild (< 10%)/mild (≥ 10%)/moderate/severe steatosis, respectively. The area under the ROC curve, sensitivity, specificity, and optimal cutoff AC value for detection of hepatic steatosis ranged from 0.843-0.926, 74.5-100.0%, 77.4-82.8%, and 0.635-0.745, respectively. Multivariate analysis revealed that the degree of steatosis was the only significant determinant factor for the AC.
Conclusions:
The AC from ATI provided good diagnostic performance in detecting the varying degrees of hepatic steatosis. The degree of steatosis was the only significant factor affecting the AC, whereas fibrosis and inflammation were not.
Key Points:
• Attenuation imaging (ATI) is based on two-dimensional grayscale ultrasound images that can incorporate into routine ultrasound examinations with less than 2 min of acquisition time. • ATI provided good diagnostic performance in detecting the varying degrees of hepatic steatosis with an area under the ROC curves ranging from 0.843 to 0.926, and there was no technical failure in this study indicating high applicability of this technique. • The degree of hepatic steatosis was the only significant factor affecting the result of ATI examination.
More Related Videos
Related Concept Videos
Transcription Attenuation in Prokaryotes
There are several different mechanisms used to attenuate transcription. In ribosome mediated...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test
Effect of Hepatic Disease on Pharmacokinetics: Dose Adjustments Due to Hepatic Impairment
Hepatic Portal System
At its core, the hepatic portal vein is the result of a confluence of the superior and inferior mesenteric veins along with the splenic vein. Each of these veins has a unique role. The superior mesenteric vein is...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):