Related Experiment Video
Updated: Jan 23, 2026

Endoscopic Ultrasound-Guided Biliary Drainage: Endoscopic Ultrasound-Guided Hepaticogastrostomy in Malignant Biliary Obstruction
Published on: March 25, 2022
EUS-Guided Choledochoduodenostomy for Distal Malignant Biliary Obstruction Using Electrocautery-Enhanced
Abdul H El Chafic1, Janak N Shah2, Chris Hamerski3
1Ochsner Medical Center, 1514 Jefferson Hwy, New Orleans, LA, 70121, USA. abdulchafic@gmail.com.
Background And Aims:
EUS-guided biliary drainage has emerged as a technique to enable endobiliary drainage in failed ERCP. A newer model, lumen-apposing metal stents (LAMS), with a cautery-enhanced delivery system became available in the USA in late 2015. This cautery-tipped version may facilitate EUS-guided choledochoduodenostomy (EUS-CD), but data using this model are lacking.
Methods:
We reviewed outcomes of attempted EUS-CD using cautery-enhanced LAMS from 6, US centers. The following data were collected: patient and procedure details, technical success, adverse events, clinical success (resolution of jaundice or improvement in bilirubin > 50%), and biliary re-interventions.
Results:
EUS-CD was attempted in 67 patients (mean age 68.8) with malignant obstruction after failed ERCP between September 2015 and April 2018. EUS-CD was technically successful in 64 (95.5%). A plastic or metal stent was inserted through the lumen of the deployed LAMS in 50 of 64 (78.1%) patients to maintain a non-perpendicular LAMS axis into the bile duct. Adverse events occurred in 4 (6.3%) and included: abdominal pain (n = 2), peritonitis that responded to antibiotics (n = 1), and bleeding requiring transfusion (n = 1). Among 40 patients with follow-up of > 4 weeks, clinical success was achieved in 100%. Biliary re-interventions for obstruction were needed in 7(17.5%), in 3 of 6 (50.0%) that underwent EUS-CD with LAMS alone versus 4 of 34 (5%) with LAMS plus an axis-orienting stent (p = 0.02).
Conclusion:
EUS-CD using LAMS with cautery-enhanced delivery systems has high technical and clinical success rates, with a low rate of adverse events. Inserting an axis-orienting stent through the lumen of the LAMS may reduce the need for biliary re-interventions.
Related Concept Videos
Bonding in Metals
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability....
Alkali Metals
Table 1: Properties of the alkali metals
Metal-Ligand Bonds
In these complexes, transition metals form coordinate covalent bonds, a kind of Lewis acid-base interaction in which both of the electrons in the bond are contributed by a donor (Lewis base) to an electron acceptor (Lewis acid). The Lewis acid in...
Properties of Transition Metals
What is an Experiment?

