Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography
Published on: January 27, 2023
Functional echocardiography training in the neonatal intensive care unit: comparing measurements and results with the
Marina Maccagnano Zamith1, Simone de Araujo Negreiros Figueira2, Allan Chiaratti de Oliveira2
1Universidade Federal de São Paulo (Unifesp), Departamento de Medicina, Divisão de Cardiologia, São Paulo, SP, Brazil.
Objectives:
Functional echocardiography is a valuable tool in the neonatal intensive care unit, but training programs are not standardized. The aim was to report an functional echocardiography training program for neonatologists and to describe the agreement of their measurements with the pediatric cardiologist.
Methods:
Functional echocardiography training lasted 32h. After training program, the neonatologists performed functional echocardiography in the neonatal intensive care unit and were required to measure left cardiac chambers dimensions, left ventricle systolic function, right and left ventricular output, ductus arteriosus diameter, and flow pattern. Images were recorded by the equipment and reviewed offline by the pediatric cardiologist. The Bland-Altman test was used for quantitative variables and the kappa test, for qualitative variables.
Results:
Twenty-two trained neonatologists performed 100 functional echocardiography exams. Ductus arteriosus identification and flow pattern had substantial agreement (kappa=0.91 and 0.88, respectively), as well as its diameter (mean difference=0.04mm). The mean difference for the aortic root was -1.2mm; left atrium, 0.60mm; left ventricle diastolic diameter, -0.90mm; left ventricle systolic diameter, -0.30mm. Shortening fraction and ejection fraction correlated well with broad limits of agreement, -2.96% (14.88; -20.82%) and --3.43% (15.54; -22.40%), respectively. Right and left ventricular output had broad limits of agreement, 16.69mL/kg/min (222.76; -189.37) and 23.57mL/kg/min (157.88; -110), respectively. There was good agreement between interpretations of normal or low cardiac output (76.7% for right ventricular output; 75.7% for left ventricular output).
Conclusion:
This functional echocardiography training program enabled neonatologists to obtain adequate skills in performing the images, obtaining good agreement with the cardiologist in simple hemodynamic measurements and ductus arteriosus evaluation.
More Related Videos
Related Concept Videos
Measurement: Standard Units
Measurement: Derived Units
Units of Measurement
There are various well-known historical measurement systems, such as the Babylonian system, the Roman system, the Egyptian system, the Olympian system, the British system, and the Indus...
Units and Standards of Measurement
Measurements of physical quantities are...
Sound Intensity
Comparative Excretory Systems