Related Experiment Video
Updated: Jan 23, 2026

Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
Determination of opiates in whole blood using microextraction by packed sorbent and gas chromatography-tandem mass
Margarida Prata1, Andreia Ribeiro1, David Figueirinha1
1Centro de Investigação em Ciências da Saúde, Faculdade de Ciências da Saúde da Universidade da Beira Interior (CICS-UBI), Avenida Infante D. Henrique, 6201-506, Covilhã, Portugal.
Abstract:
In Portugal, and worldwide, the abuse of psychoactive substances is increasing, with a significant incidence of deaths related to their consumption. Opiates are one of the most prevalent group of substances in that context, and they are responsible for a significant impact of the mentioned harms. Therefore, it becomes necessary to equip labs with faster and effective methods to identify and quantify these substances. This work describes the development and validation of a novel analytical method for the simultaneous determination of morphine, codeine and 6-monoacetylmorphine in blood samples by gas chromatography-tandem mass spectrometry (GC-MS/MS), using microextraction by packed sorbent (MEPS) for sample preparation. Before the MEPS procedure, a precipitation step with acetonitrile was performed. The MEPS parameters were optimized using the fractional factorial planning (2k-1) and surface response methodology. The final optimized conditions were: number of strokes (20), amount of formic acid in the washing solution (3.36%), number of washes of the sorbent (1), amount of ammonium hydroxide in the elution solution (2.36%) and number of elution cycles (11). After the extraction procedure, the analytes were derivatized with MSTFA with 5% TMS. Using a sample volume of 250 μL, the method was validated according to internationally accepted standards. The method proved to be linear in the range of 5-1000 ng/mL with coefficients of determination greater than 0.99 for all analytes. Intra-and inter-day precision and accuracy were in accordance with the above-mentioned criteria, presenting coefficients of variation ≤15% and relative errors within a range of ± 15% of the theoretical concentration. The absolute recoveries ranged from 6 to 23%. The validated method was applied to the analysis of real samples, being an advantageous tool for the detection of those substances in blood. This is the first time that GCMS/MS with MEPS was used for the determination of these compounds in biological fluids.
More Related Videos
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
08:14Extraction of Non-Protein Amino Acids from Cyanobacteria for Liquid Chromatography-Tandem Mass Spectrometry Analysis
Published on: December 9, 2022
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Tandem Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II