Related Experiment Video
Updated: Jan 23, 2026

Single Port Donor Nephrectomy
Published on: March 12, 2011
Single-port thoracoscopic wedge resection using the Endo GIA Radial Reload: outcome of 15 cases
1Department of Thoracic Surgery, Chigasaki Municipal Hospital, Chigasaki, Kanagawa, Japan.
Background:
We previously described the technique for single-port thoracoscopic lung wedge resection using the Endo GIATM Radial Reload surgical stapler. The GIA Radial Reload has a curved cut line that is perpendicular to the direction of instrument insertion, facilitating the approach to the lung tissue behind the lesion. Herein, we report the outcomes of 15 cases using this procedure.
Methods:
Between August 2016 and February 2018, 15 patients underwent single-port thoracoscopic wedge resection using the Endo GIA Radial Reload. Single-port thoracoscopic surgery was performed through 3-5-cm incisions. For the first stapler, we used a GIA Radial Reload cartridge. For the second and subsequent staplers, we used the GIA Radial Reload cartridge or a straight cartridge based on the direction of the cut.
Results:
In one patient, we extended the incision up to 7 cm and performed video-assisted thoracotomy because the lesion was too small to find. In the other 14 patients, the procedure was completed through a 3-5-cm port. In one patient, we added a suture for air leakage detected intraoperatively. Postoperative air leakage occurred in two patients. These three patients had emphysema based on computed tomography. In the remaining 12 patients, no air leakage was found and the chest tube was removed on postoperative day 1.
Conclusions:
This procedure is suitable for resecting small nodules, because palpation with two fingers is easy. The GIA Radial Reload cartridge may not be a good choice for emphysematous lung, because air leakage sometimes occurs.
More Related Videos
Related Concept Videos
Wedges
Consider using a wedge to lift a heavy slab. Here, the wedge functions by converting the applied force into a much larger force directed almost perpendicular to the initial force. This...
Other Nuclides: 31P, 19F, 15N NMR
While fluorine-19 and phosphorous-31 have high natural abundances (100%) and positive gyromagnetic ratios, nitrogen-15 has a low natural abundance and a negative gyromagnetic ratio. However, nitrogen-15 is still preferred over nitrogen-14 (which has a...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Predicting Reaction Outcomes
Outcomes of Glycolysis
Cellular respiration can occur aerobically (with oxygen) or anaerobically (without oxygen). In the presence of oxygen, cellular respiration starts with glycolysis and continues with pyruvate...

