Feasibility of Spinal Anesthesia Placement Using Automated Interpretation of Lumbar Ultrasound Images: A Prospective
Priyanka Singla1, Adam J Dixon2,3, Jessica L Sheeran1
1Department of Anesthesiology, University of Virginia Health System, Charlottesville, VA 22908, Virginia, USA.
Background:
This study evaluated the efficacy of spinal anesthesia administration by resident physicians when using an ultrasound system with automated neuraxial landmark detection capabilities.
Methods:
150 patients were enrolled in this trial. Anesthesiology residents placed spinals in subjects undergoing scheduled cesarean delivery using one of three techniques to identify neuraxial landmarks: palpation, ultrasound, or combined palpation and ultrasound. Ultrasound was performed using a handheld system that automatically identified neuraxial landmarks (e.g. midline, intervertebral spaces). All residents watched a 10-minute video and received 20 minutes of hands-on training prior to participating in the study. First insertion success rate was the primary end point.
Results:
Among all patients, use of ultrasound resulted in a 11% greater first-insertion success rate (RR: 1.11 [0.85-1.47], p=0.431), a 15% reduction in needle insertions (RR: 0.85, p=0.052), and a 26% decrease in needle passes (RR: 0.74, p=0.070). In obese patients of BMI ≥ 30 kg/m2, use of ultrasound resulted in 26% greater first-insertion success rates (RR: 1.26, p=0.187), a 21% decrease in needle insertions (RR: 0.79, p=0.025), a 38% decrease in needle passes (RR: 0.62, p=0.030), and a 75% decrease in patients reporting neutral or low patient satisfaction with anesthesia administration (RR: 0.25, p=0.004).
Discussion:
Resident anesthesiologists competently utilized the ultrasound system after receiving minimal training. Technical endpoints and patient satisfaction trended towards improvement when ultrasound was used prior to spinal placement, with stronger trends observed in obese patients. Additional study is required to fully characterize the impact of the ultrasound system on clinical efficacy.
Related Concept Videos
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the...
Local Anesthetics: Clinical Application as Spinal Anesthesia
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...