Deformation patterns in WorldSID 50th percentile dummy instrumented with IR-TRACC and RibEye™ in different loading
Anil Kalra1, Jason Greb1, Agnes Kim1
1a Research and Innovation Center , Ford Motor Company , Dearborn , Michigan.
Abstract:
Objective: The purpose of this study was to investigate the effect of different loading configurations on the WorldSID 50th percentile male dummy instrumented either with the Infra-Red Telescoping Rod for the Assessment of Chest Compression (IR-TRACC) or the RibEye™ rib deflection measurement system. Methods: The optical sensors of the RibEye system were used to capture the multipoint deformation of the dummy at frontal and rearward off-center locations in addition to the center of the rib location. The experimental setup consisted of 2 types of loadings: Low severity and high severity. Low-severity loading was performed by deploying a fixture-mounted side airbag on the dummy and high-severity loading was achieved by deploying a driver front airbag mounted in a similar fashion. The low-severity condition aimed at deforming the dummy's ribs locally at off-center locations where the RibEye light emitting diodes (LEDs) were positioned to capture the deformations at those locations. The high-severity condition aimed at loading the dummy at high speed in lateral and oblique directions similar to what is experienced by dummies in side impacts. Results: In the low-severity tests, the peak deflections, in terms of length change, were approximately 15-20 mm, whereas for the high-severity cases the peak deflections were in the range of 30-40 mm for both IR-TRACC and RibEye cases. Conclusions: For similar physical insults, dummies with the IR-TRACC and RibEye systems showed varying results for both length changes and the shoulder forces depending on the severity and direction of loading. Under purely lateral loading, the mid-length changes with the RibEye and the 1D IR-TRACC were comparable. In the oblique loading conditions, more differences were seen with the 2 systems depending on the impact direction. The shoulder forces consistently differed between the 2 systems. In the frontal oblique low-severity cases, the ribs pivoted along the spine end and the length change was not found to be a suitable parameter to quantify rib deformation in such loading scenarios.
Related Concept Videos
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Deformation of a Beam under Transverse Loading
The insights from the bending moment diagram extend to...
Percentile
Electron Configurations
The relative energies of the subshells determine the order in which atomic orbitals are filled (1s, 2s, 2p, 3s, 3p,...
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
Electron Configuration of Multielectron Atoms