Related Experiment Video
Updated: Jan 23, 2026

Thermal Measurement Techniques in Analytical Microfluidic Devices
Published on: June 3, 2015
Design by Monte Carlo method of a thermal neutron device using a 241Am/9Be source and high-density polyethylene
Lenin E Cevallos-Robalino1, Gonzalo F García-Fernández2, Alfredo Lorente2
1Departamento de Ingeniería Energética, ETSI Industriales, Universidad Politécnica de Madrid, José Gutiérrez Abascal 2, 28006, Madrid, Spain; Grupo de Investigación en Sistemas de Control y Robótica, GISCOR, Universidad Politécnica Salesiana, C. Robles 107 Chambers, 090108, Guayas, Guayaquil, Ecuador.
Abstract:
A thermal neutron system intended to be used in neutron activation analysis has been designed by Monte Carlo methods. The device is based on a241Am/9Be neutron source of 111 GBq, placed inside a cylindrical cavity open inside a parallelepiped of moderator material. Three different moderator materials, water, graphite and high-density polyethylene (HDPE), were simulated to check what is the most suitable for the detection system, concluding that HDPE reach the better performance. The device achieves an increased thermal neutron flux by taking advantage of neutron moderation in the polyethylene and the neutron scattering in the irradiation chamber walls. The thermal fluence rates obtained were 904 cm-2 s-1, i.e. 8.144 cm-2 s-1 GBq-1, with a fraction of thermal neutrons at the best point of 83% of pristine fast neutrons emitted by the source. The device has been designed by Monte Carlo techniques using the MCNP6 code, and the main tasks developed were to select the moderator material and to maximize the thermal neutrons flux in the irradiation chamber.
More Related Videos
Related Concept Videos
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
Methods of Documentation I: Source-Oriented Records
In an SOR, each discipline involved in patient care maintains a separate medical record section. This record-keeping method enables easy tracking of patient progress and ensures healthcare staff have access to up-to-date information.
Key Attributes include the following:
Design Example: Identifying the Locations of Monuments in the Field Using Global Positioning System Device
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...
Group Design
Thermal Strain