A Preliminary Study of Neonatal Cranial Venous System by Color Doppler
Lu Yang Liu1, Jin Ling Hong1, Chang Jun Wu1
1First Affiliated Hospital of Harbin Medical University, 150001, No. 23 You Zheng Street, Harbin, Heilongjiang, China.
Aim:
To present anatomic data in the ultrasound planes for the identification of the major veins and the venous sinuses in cerebrum and to establish the sonographic normal reference values for the visualization of vein vessels and vein sinuses and blood flow velocities.
Methods:
This study involved 55 healthy full-term neonates for transfontanellar color Doppler sonography. The imaging included both sagittal and coronal planes with LA332E probe, supplemented with PA240 probe as necessary. As low as reasonably achievable (ALARA) principle was obeyed, limiting Doppler exposure time and maximizing signal intensity by increasing gain rather than outputting transducer power settings. The output power was kept at a minimum level consistent with recording an adequate signal. Keeping the newborns in calm state, the total examination time which every neonate required was less than 5 min. All images were stored also in a workstation for further analysis. The description statistics and t-test for statistical analysis were used.
Result:
In all studied cases (100% cases), subependymal veins (SV), internal cerebral veins (ICV), Galen vein (GV), straight sinus (SS), superior sagittal sinus (SSS), and transverse sinuses (TS) were visualized. The visualization percentages of inferior sagittal sinus (ISS) or basal veins/Rosenthal veins (BV/RV) were lower than 100%. Based on vessel visualization percentage from high to low, the vessels were ordered as follows: SV, ICV, BV, SS, TS, ISS, and SSS. In SSS and TS, the pulsation percentage was 100%. The descending percentages of vessel pulsation were noted in SS, BV, ICV, and SV. On the basis of the mean of maximum velocities of the vessels from low to high, the vessels were ordered as follows: ISS, BV-L, BV-R, ICV-R, ICV-L, SV-L, SV-R, SSS, TS-L, TS-R, and SS.
Conclusion:
The measurements percent of visualization of cerebral deep veins was higher than the percent of cerebral venous sinuses. The pulsation percent of measurement and the velocities of cerebral venous sinuses were absolutely higher than the cerebral deep venous system. The pairs of vascular blood flow velocities were nonsignificantly different from one another.
Related Concept Videos
Doppler Effect - I
Doppler Effect - II
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Color Vision
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...