Diagnostic performance of thromboelastometry in trauma-induced coagulopathy: a comparison between two level I trauma
Pierre Bouzat1,2,3, Romain Guerin4, Bastien Boussat5,6,7
1Department of Anaesthesiology and Intensive Care Medicine, Grenoble Alps Trauma Centre, Grenoble University Hospital, 38000, Grenoble, France. PBouzat@chu-grenoble.fr.
Purpose:
The implementation of a ROTEM®-based algorithm requires reliable thresholds to mirror a prothrombin time (PT) ratio > 1.2 and/or a fibrinogen concentration < 1.5 g l-1. Our goal was to compare the diagnostic performances of two devices (ROTEM® Sigma and Delta, IL Werfen, Munich, Germany) in two level-I trauma centres for the diagnostic of post-traumatic coagulopathy.
Methods:
We conducted a retrospective analysis of two registries across two periods of time: from September 2014 to December 2015 in Lyon-Sud university trauma centre and from April 2016 to January 2018 in the Grenoble Alps Trauma Centre. Accuracies of EXTEM and FIBTEM assays to detect patients with coagulation disorders were tested for each device using receiver operating characteristic (ROC) analyses.
Results:
Within the study period, 74 trauma patients in the Grenoble cohort and 75 trauma patients in the Lyon cohort had concomitant ROTEM® and standard coagulation testing on admission. No statistically significant difference was found between the two ROC curves for FIBTEM amplitude at 5 min (A5), FIBTEM maximum clot firmness, EXTEM clotting time (CT) and EXTEM A5 for ROTEM® Sigma and Delta to diagnose post-traumatic coagulation disorders. The best threshold for FIBTEM A5 to predict low fibrinogen concentration was 7 mm for each device. EXTEM CT thresholds to diagnose PT ratio > 1.2 were 78 s and 74 s for ROTEM® Sigma and Delta, respectively.
Conclusions:
These results suggest that ROTEM®-based algorithms may be transposed from one trauma centre to another independently of the setting and the ROTEM® device in use.
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
High-Level and Low-Level Awareness
Leveling Effect
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...