Related Experiment Video
Updated: Jan 23, 2026

Multiplexed Fluorescent Microarray for Human Salivary Protein Analysis Using Polymer Microspheres and Fiber-optic Bundles
Published on: October 10, 2013
Optical Fiber-Mediated Immunosensor with a Tunable Detection Range for Multiplexed Analysis of Veterinary Drug
Rongbin Nie1, Xuexue Xu1, Yiping Chen2
1Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Department of Chemistry , Northeast Normal University , 5268 Renmin Street , Changchun , Jilin Province 130024 , PR China.
Abstract:
We describe herein a newly developed chemiluminescent optical fiber immunosensor (OFIS) with a tunable detection range for multiplexed analysis of veterinary drug residues with vastly different concentrations in milk samples. The optical fiber probe is used as a carrier of biorecognition element as well as a transducer, enabling a low-cost compact design, which makes this system suitable for cost-effective on-site detection of the target analytes. Importantly, the synergy between modulation of the length of the optical fiber sensing region and the number of fibers allows performing multiplexed immunoassays in an easily controllable manner over a tunable detection range from pg/mL to μg/mL analyte concentrations. By combining the optical fiber sensor with a nanocomplex signal amplification system, a highly sensitive chemiluminescent OFIS system is demonstrated for the multiplexed assaying of veterinary drug residues in milk samples with linear ranges of 10-(2 × 104) pg/mL for chloramphenicol, 0.5-500 ng/mL for sulfadiazine, and 0.1-300 μg/mL for neomycin. This controllable strategy, based on modulation of the fiber probe, provides a versatile platform for multiplexed quantitative detection of both low-abundance and high-abundance targets, which shows great potential for on-site testing in food safety.
Related Concept Videos
Residual Stresses
Residual Plots
When the residual values are plotted against the variable x, it is called a residual...
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
Residual Stresses in Circular Shafts
Therapeutic Drug Monitoring: Drug Analysis Methods
¹H NMR: Long-Range Coupling
In alkenes, spin information is communicated via σ–π overlap, as seen in allylic (four-bond) and homoallylic (five-bond) couplings. These coupling interactions are stronger when the σ bond is parallel to the alkene...