Related Experiment Video
Updated: Jan 23, 2026

Determination of the Transport Rate of Xenobiotics and Nanomaterials Across the Placenta using the ex vivo Human Placental Perfusion Model
Published on: June 18, 2013
[Impedance Spectroscopy and Transcriptome Analysis of Choriocarcinoma BeWo b30 as a Model of Human Placenta]
S V Nikulin1,2,3, E N Knyazev1, T N Gerasimenko1
1OOO SRC Bioclinicum, Moscow, 115088 Russia.
Abstract:
Placenta is a highly specialized organ that is necessary for successful gestation. Several models of the placental barrier are used to study how it functions, including the transplacental transport of xenobiotics. One of these models, human choriocarcinoma cell line BeWo is widely used in vitro. Notably, cancerous BeWo cells form multilayer structures that normally are not found in the human placenta. Here, we aim to develop techniques suitable for monitoring BeWo b30 cells in culture. To assess the state of BeWo b30 cells growing on a membrane, we use impedance spectroscopy, which allows us to estimate the number of cell layers by the change in the electrical parameters of the biological system. In mature BeWo b30 cell cultures, we also note a significant increase in the expression of genes encoding metallothioneins (particularly, MT1B, MT1F, and MT2A) and syncytins (ERVW-1 and ERVFRD-1), which can be used as biomarkers reflecting the development of mature phenotypic characteristics, namely, trophoblastic invasion and formation of the syncytium.
Related Concept Videos
Impedance Combination
Impedances and Admittance
Impedance is a measure of resistance to sinusoidal current flow in an AC circuit. Unlike their behavior in DC circuits, where inductors appear as short circuits and capacitors as open circuits, the behavior of these components in AC...
Series Impedances: Three-Phase Line
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
RLC Series Circuits: Impedance