Diaphragm electromyography results at different high flow nasal cannula flow rates
Eleanor Jeffreys1,2, Katie A Hunt1,2, Theodore Dassios1,3
1Women and Children's Health, School of Life Course Sciences, Faculty of Life Sciences and Medicine, King's College London, London, WC2R 2LS, UK.
Abstract:
Heated, humidified, high-flow nasal cannula (HHHFNC) is increasingly being used, but there is a paucity of evidence as to the optimum flow rates in prematurely born infants. We have determined the impact of three flow rates on the work of breathing (WOB) assessed by transcutaneous diaphragm electromyography (EMG) amplitude in infants with respiratory distress or bronchopulmonary dysplasia (BPD). Flow rates of 4, 6 and 8 L/min were delivered in random order. The mean amplitude of the EMG trace and mean area under the EMG curve (AEMGC) were calculated and the occurrence of bradycardias and desaturations recorded. Eighteen infants were studied with a median gestational age of 27.8 (range 23.9-33.5) weeks and postnatal age of 54 (range 3-122) days. The median flow rate prior to the study was 5 (range 3-8) L/min and the fraction of inspired oxygen (FiO2) was 0.29 (range 0.21-0.50). There were no significant differences between the mean amplitude of the diaphragm EMG and the AEGMC and the number of bradycardias or desaturations between the three flow rates.Conclusions: In infants with respiratory distress or BPD, there was no advantage of using high (8 L/min) compared with lower flow rates (4 or 6 L/min) during support by HHHFNC. What is known: • Humidified high flow nasal cannulae (HHHFNC) is increasingly being used as a non-invasive form of respiratory support for prematurely born infants. • There is a paucity of evidence regarding the optimum flow rate with 1 to 8 L/min being used. What is new: • We have assessed the work of breathing using the amplitude of the electromyogram of the diaphragm at three HHHFNC flow rates in infants with respiratory distress or BPD. • No significant differences were found in the EMG amplitude results or the numbers of bradycardias or desaturations at 4, 6 and 8 L/min.
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Gene Flow
Renal Drug Excretion: Effect of Urine pH, Flow Rate, and Drug pKa
The pKa of a...
Blood Flow
Couette Flow