Related Experiment Video
Updated: Jan 23, 2026

A Comprehensive Protocol for Manual Segmentation of the Medial Temporal Lobe Structures
Published on: July 2, 2014
Medial Buttress Plating for Humerus Fractures With Unstable Medial Column
1Department of Orthopaedic Surgery, Yeungnam University Hospital, Yeungnam University College of Medicine, Daegu, Korea.
Abstract:
The purpose of this study was to report surgical tips and techniques on the use of additional medial buttress plate fixation in proximal humeral fractures with unstable medial column restoration after lateral locking compression plate fixation. Between April 2011 and January 2017, 17 patients with medial cortical deficiency were treated using this technique. The average follow-up period was 30 (range, 12-81) months. Successful fracture healing was achieved in all 17 cases. The mean neck-shaft angle change was 1.33 degree (range, 0-7.4 degree). Anterior glenoid rim erosion occurred in 1 patient. No avascular necrosis of the humeral head or significant loss of reduction, and no implant failure or screw perforation occurred. In the first part of this study, we described in detail the indications and surgical technique applied to these fractures. In the second part, we reviewed the clinical and radiographic outcomes of these patients. Supplemental medial buttress plate fixation after lateral locking compression plate fixation was effective in preventing varus collapse and implant failure for proximal humeral fractures with an unstable medial column.
Related Concept Videos
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
Bones of the Upper Limb: Humerus
Muscles of the Vertebral Column
Superficial Layer:
The superficial layer consists primarily of the splenius muscles, which include the splenius capitis and splenius cervicis. These muscles are mainly responsible for the head and cervical spine movements, including extension, rotation, and lateral bending. The splenius capitis...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...

