Self-monitoring of intraocular pressure using Icare HOME tonometry in clinical practice
Barbara Cvenkel1,2, Makedonka Atanasovska Velkovska1
1Department of Ophthalmology, University Medical Centre Ljubljana, Ljubljana, Slovenia.
Abstract:
Purpose: To determine the value of self-monitoring of diurnal intraocular pressure (IOP) by Icare Home rebound tonometer in patients with glaucoma and ocular hypertension. Methods: Patients with open-angle glaucoma or ocular hypertension, controlled IOP at office visits, and at least 3 years of follow-up in the glaucoma clinic were included. Progression of glaucoma was based on medical records and defined by documented structural and/or visual field change. Patients were trained to correctly perform self-tonometry and instructed to measure diurnal IOP in a home setting for 3 days. IOP characteristics (mean, peak IOP, fluctuation of IOP as range, and SD of IOP) were documented and compared between the progressive and stable eyes. Results: Ninety-four patients (50 females) with a mean (SD) age of 57.1 (14.7) years were included. Among the 94 eyes from 94 subjects, 72 (76.6%) eyes had primary open-angle glaucoma, ten (10.6%) had pigmentary glaucoma, four (4.3%) had exfoliative glaucoma, and eight (8.5%) eyes had ocular hypertension. Thirty-six eyes showed progression and 58 eyes were stable. Patients with progression were older than those with stable disease (mean (SD) 65.8 (8.4) years vs 51.7 (15.3) years, P<0.001). The progression group had higher average IOP (mean (SD) 15.8 (4.0) mmHg vs 13.3 (3.7) mmHg, P=0.002), peak IOP (mean (SD) 21.8 (5.8) mmHg vs 18.6 (4.8) mmHg, P=0.01), and greater IOP fluctuation range (mean (SD) 11.6 (4.8) vs 9.1 (3.5) mmHg, P=0.011) compared to non-progression group. Conclusion: Self-monitoring of IOP using Icare Home tonometry provides more complete data on variability of IOP to assist in the management of glaucoma.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Constant Pressure Calorimetry
Vapor Pressure
Characteristics of Practical Op Amps
The ratio of differential gain to the common-mode gain is defined as the common-mode rejection ratio (CMRR). This ratio quantifies the ability of operational amplifiers (op-amps) to reject common-mode...
Theoretical Foundations of Nursing Practice
Theories provide a perspective to assess patients' conditions and organize data and methods. They also assist in analyzing and interpreting information. They represent a...
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer