Related Experiment Video
Updated: Jan 23, 2026
![Assessment of Gastric Emptying in Non-obese Diabetic Mice Using a [13C]-octanoic Acid Breath Test](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F50301.jpg&w=3840&q=50)
Assessment of Gastric Emptying in Non-obese Diabetic Mice Using a [13C]-octanoic Acid Breath Test
Published on: March 23, 2013
Comparing radiopaque markers and 13C-labelled breath test in diabetic gastroparesis diagnostics
Dag A Sangnes1,2,3, Eirik Søfteland1,4, Tonje Teigland1,5
1Department of Medicine, Haukeland University Hospital, Bergen, Norway.
Abstract:
Purpose: Determining gastric emptying is mandatory in the diagnosis of diabetic gastroparesis. Several methods of investigation exist, but none has proven reliable, inexpensive and accessible. In this study, we aimed to compare gastric emptying of radiopaque markers (ROM) and 13carbon-labelled gastric emptying breath tests for solids (GEBT). We also aimed to determine any association between gastric emptying and patient-reported symptoms, glycemic control and the patients' age, diabetes duration and occurrence of other late complications. Patients and methods: Forty-five patients (30 women, 15 men) with diabetes mellitus types 1 or 2 (40, 5) and symptoms of gastroparesis were examined with ROM and GEBT. All were interviewed, filled out symptom questionnaires and had HbA1c levels measured. Results: Forty percent of patients had delayed gastric emptying of ROM, while 55% had delayed gastric emptying of GEBT. Correlation between ROM and GEBT was not significant. Compared to GEBT, sensitivity for a positive ROM test was 0.52, while specificity was 0.74. In women, we found a higher specificity of 0.92, sensitivity 0.47. Difference in HbA1c between patients with positive and negative results was of borderline significance for both tests. GEBT (r=0.41, P=0.008) correlated with HbA1c. Patients with any late complications of diabetes had higher gastric retention of ROM (P=0.028), while patients with polyneuropathy (P=0.014) and diabetic wounds (P=0.004) had slower emptying with GEBT. None of the methods identified significant associations between gastric emptying and symptom scores, age or diabetes duration. Conclusions: As a measure of gastric emptying, the ROM test has benefits of being affordable and available. Compared to GEBT, the method has low diagnostic reliability. Before continued use, we recommend additional studies validating the test in diabetes patients.
More Related Videos
Related Concept Videos
Breathing
Pathophysiology of Diabetes
Type 1 diabetes is characterized by autoimmune-mediated destruction of pancreatic β cells, with environmental factors potentially triggering this process in genetically susceptible individuals. Despite many not having a family history, certain genes increase susceptibility,...
Mechanism of Breathing II: Expiration
Expiration, or exhaling, is a complex physiological process that begins as the inspiratory muscles begin to relax. This relaxation triggers a series of events that epitomize the efficiency of the respiratory system.
Mechanism of Expiration:
Mechanism of Breathing I: Inspiration
The respiratory system, an essential network for breathing, comprises the conducting and respiratory zones, each playing a crucial role in the overall process of respiration. Let us explore the detailed mechanism of inspiration, or inhalation, which is the first phase of the respiratory cycle.
Pathway of Air during Inspiration
During inspiration, air enters our body through the nose or mouth and moves through the conducting zone,...
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Comparing the Survival Analysis of Two or More Groups

