Related Experiment Video
Updated: Jan 23, 2026

In situ Subcellular Fractionation of Adherent and Non-adherent Mammalian Cells
Published on: July 23, 2010
Contraception with estradiol valerate and dienogest: adherence to the method
Franca Fruzzetti1, Anna Maria Paoletti2, Tiziana Fidecicchi1
1Department of Obstetrics and Gynecology, Pisa University Hospital, Pisa, Italy.
Abstract:
Purpose: The aim of the study was to examine the discontinuation rate of hormonal contraception with estradiol valerate (E2V) and dienogest (DNG). Patients and methods: We collected data at the Family Planning Clinics of the Departments of Obstetrics and Gynecology of Pisa and Cagliari. We included in the analysis 354 consecutive women using oral contraceptive pills containing E2V and DNG. We analyzed the rate and the reason for discontinuation, classifying the reasons in 5 categories: 1) minor side effects, 2) adverse events, 3) other events not directly caused by the drug or conditions for which the pill could represent a risk factor, 4) no compliance with the method and 5) no further need. Results: Of the 354 women examined, 50.8% had discontinued E2V/DNG pill. Excluding women who stopped the pill because of no further need (10.5%), 27.4% discontinued because of minor side effects, 1.7% discontinued for adverse events, 9.9% because of other events not directly caused by the drug or conditions for which the pill could represent a risk factor and 1.4% because of difficulties with compliance. Irregular bleedings were the main reasons reported for discontinuation. The time to discontinuation for irregular bleedings was significantly (p<0.02) longer in adults than in adolescents and slightly but not significantly longer in women who received information about this possible effect. Conclusion: Unacceptable cycle control was the principal cause of discontinuation of pill with E2V and DNG. An appropriate information about this possible effect may improve adherence to this combined oral contraceptive.
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
The Scientific Method
The Scientific Method
Generally, predictions are tested using carefully-designed experiments. Based on the outcome of these...
The Scientific Method
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Curing Methods

