Introduction:
Jones fractures pose many challenges for the treating surgeon and can cause significant disability for some patients. The aim of this study was to review the results of using a variable angle locking compression plate as an alternative fixation method in the treatment of Jones fractures.
Methods:
A retrospective chart review was conducted of patients who had undergone fixation of Jones fracture with a variable angle locking compression plate from September 2012 through February 2016. Radiographs of the preoperative and six-week postoperative and postoperative follow-up outcomes, including complication and hardware removal, were collected.
Results:
Twenty-three cases met the inclusion/exclusion criteria. The overall bony union rate was 96% at six-week postoperative and 100% at 20-week postoperative. Mean age was 30 ± 16 years, and mean BMI was 30.7 ± 5.2 kg/m2. Three patients (13%) had plate removal: two (9%) were due to irritation caused by shoe wearing and one patient (4%) had a skin infection (cellulitis) which was treated with intravenous antibiotics. One patient (4%) had developed deep vein thrombosis (DVT) that was resolved with anticoagulant without implant removal. No fixation loss and no associated complications developed from implant removal.
Conclusions:
Based on our limited experience, this study provided evidence that the variable angle locking compression plate may be an alternative form of fixation for Jones fractures with a low complication rate. This procedure seemed to provide a safe, reliable method that can achieve an anatomic reduction, stable fixation, rapid healing, and good results in the treatment of Jones fractures.
More Related Videos
05:45Author Spotlight: Exploring Regeneration in Axolotls Through Insights in Cellular and Molecular Mechanisms, Bone Healing, and Implications for Human Therapies
Published on: April 12, 2024
09:00Experimental Methods for Spin- and Angle-Resolved Photoemission Spectroscopy Combined with Polarization-Variable Laser
Published on: June 28, 2018
Related Concept Videos
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Resistors In Series
In a series circuit, the...
Alternative RNA Splicing
There are five types of alternative RNA splicing that vary in the ways the pre-mRNA segments are removed or retained in the mature mRNA. The first...
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Series Resonance